Combined application of heterologous collagen and fibrin sealant for liver injuries

作者: Heinz Jakob , Charles D. Campbell , Axel Stemberger , Ingrid Wriedt-Lübbe , Günter Blümel

DOI: 10.1016/0022-4804(84)90143-4

关键词:

摘要: Hemostasis in complex liver injuries remains a problem despite improvements operative techniques including debridement, suturing or packing. To evaluate fibrin sealant (FS), new biodegradable hemostatic agent combination with porcine collagen for sealing of injuries, three series experiments were performed 132 rats. In I, 18 rats had 10-mm diameter and 2-mm depth punch defect to the left lateral lobe. FS group (n = 9), bleeding was treated by insertion an FS-soaked piece equal size which firmly attached plastic disk wire anchor. control alone inserted. Fifteen minutes after lobe excised pull-off simultaneous script chart recording. There highly significant difference adhesion surface (85.6 ± 7.1 versus 24.8 2.6 g/cm2 group, P < 0.001). II, 42 anticoagulated (Coumadin, PT 27.5% 1.3) lobectomy rupture placed groups 14). Group I FS, II collagen, III catgut sutures served as controls. Fourteen days later 12 13 7 alive yielding 85.7, 92.8, 50% overall survival rates, 0.05 III. III, 72 non-anticoagulated identically examined morphologically at 1, 7, 28, 56 days. Twenty-eight surgery FS-collagen compound completely absorbed without foreign body reaction extensive fibrosis. It concluded that strongly adheres surfaces may enhance causing inflammatory allogenic reactions.

参考文章(11)
Richard H. Carmona, Robert C. Lim, Gary C. Clark, Morbidity and mortality in hepatic trauma The American Journal of Surgery. ,vol. 144, pp. 88- 94 ,(1982) , 10.1016/0002-9610(82)90607-9
James A. Svoboda, Edward T. Peter, Chau V. Dang, Steven N. Parks, John H. Ellyson, Severe liver trauma in the face of coagulopathy: A case for temporary packing and early reexploration American Journal of Surgery. ,vol. 144, pp. 717- 721 ,(1982) , 10.1016/0002-9610(82)90557-8
DAVID V. FELICIANO, KENNETH L. MATTOX, GEORGE L. JORDAN, Intra-abdominal packing for control of hepatic hemorrhage: a reappraisal. Journal of Trauma-injury Infection and Critical Care. ,vol. 21, pp. 285- 290 ,(1981) , 10.1097/00005373-198104000-00005
Mogens Lykkegaard Nielsen, Thorkild Mygind, Selective arterial embolization in traumatic hemobilia World Journal of Surgery. ,vol. 4, pp. 357- 359 ,(1980) , 10.1007/BF02393406
M. Balasegaram, Suresh K. Joishy, Hepatic resection: The logical approach to surgical management of major trauma to the liver American Journal of Surgery. ,vol. 142, pp. 580- 583 ,(1981) , 10.1016/0002-9610(81)90430-X
Boris V. Petrovsky, Vladimir S. Gigaury, Oleg B. Milonov, Michael I. Perelman, Vyacheslav E. Mlinchik, Sergey V. Gotye, Iskandar S. Safarov, Surgical application of tissue adhesives. World Journal of Surgery. ,vol. 4, pp. 331- 335 ,(1980) , 10.1007/BF02393395
Carl E. Bredenburg, Carl E. Bredenburg, Paul M. James, Paul M. James, Robert W. Anderson, Robert W. Anderson, Fred Leonard, Fred Leonard, Sidney A. Levitsky, Sidney A. Levitsky, John A. Collins, John A. Collins, Robert M. Hardaway, Robert M. Hardaway, Cyanoacrylate adhesives as topical hemostatic aids. II. Clinical use in seven combat casualties. Surgery. ,vol. 65, pp. 260- 263 ,(1969) , 10.5555/URI:PII:0039606069900828
Stenzl W, Hermann W, Höllerl G, Dacar D, Tscheliessnigg Kh, Höfler H, [Hemostasis in the liver induced with tissue glue - comparison of 2 glue-component combinations]. Zentralblatt Fur Chirurgie. ,vol. 107, pp. 1557- ,(1982)
Campbell Cd, Pick R, Replogle Rl, Jakob H, Qiu Zk, Evaluation of fibrin sealing for cardiovascular surgery. Circulation. ,vol. 70, ,(1984)
Olsen Wr, Late complications of central liver injuries. Surgery. ,vol. 92, pp. 733- 743 ,(1982)