Tendon and Ligament Fixation to Bone

作者: Christopher M. Hill , Yuehuei H. An , Frank A. Young

DOI: 10.1385/1-59259-942-7:257

关键词:

摘要: For the successful transplantation or transposition of ligaments and tendons, fixation techniques are very important. As most postsurgical rehabilitation protocols emphasize immediate full range motion early return to function, must provide adequate strength stiffness during postoperative period. Table 1 lists mechanical properties (failure load, ultimate strength, stiffness, elastic modulus) ligament, tendon, deep fascia different species. Ideally, should meet exceed requirements for normal activity on tendons. In addition, not interfere with healing be biocompatible long-term use easily removable (1). Large animals (goats, dogs, sheep, pigs, monkeys) common species studies ligament tendon fixation. bone volume these is important factor facilitation instrumentation (fixations screws implants). Selected animal models from literature evaluate listed in 2.

参考文章(129)
W G Clancy, R G Narechania, T D Rosenberg, J G Gmeiner, D D Wisnefske, T A Lange, Anterior and posterior cruciate ligament reconstruction in rhesus monkeys. Journal of Bone and Joint Surgery, American Volume. ,vol. 63, pp. 1270- 1284 ,(1981) , 10.2106/00004623-198163080-00008
P St Pierre, E J Olson, J J Elliott, K C OʼHair, L A McKinney, J Ryan, Tendon-healing to cortical bone compared with healing to a cancellous trough. A biomechanical and histological evaluation in goats. Journal of Bone and Joint Surgery, American Volume. ,vol. 77, pp. 1858- 1866 ,(1995) , 10.2106/00004623-199512000-00010
Thomas B. Aufdemorte, Gordon I. Groh, Gerald R. Williams, Charles A. Rockwood, Michael A. Wirth, James Lee Chong Hwa, Michael Clem, Kozo Ono, Repair of soft tissue to bone using a biodegradable suture anchor Orthopedics. ,vol. 20, pp. 1051- 1055 ,(1997) , 10.3928/0147-7447-19971101-10
F R Noyes, D L Butler, E S Grood, R F Zernicke, M S Hefzy, Biomechanical analysis of human ligament grafts used in knee-ligament repairs and reconstructions. Journal of Bone and Joint Surgery, American Volume. ,vol. 66, pp. 344- 352 ,(1984) , 10.2106/00004623-198466030-00005
Petteri Kousa, Teppo L.N. Järvinen, Pekka Kannus, Pia Ahvenjärvi, Auvo Kaikkonen, Markku Järvinen, A bioabsorbable plug in bone-tendon-bone reconstruction of the anterior cruciate ligament: Introduction of a novel fixation technique. Arthroscopy. ,vol. 17, pp. 144- 150 ,(2001) , 10.1053/JARS.2001.20097
S A Rodeo, S P Arnoczky, P A Torzilli, C Hidaka, R F Warren, Tendon-healing in a bone tunnel: a biomechanical and histological study in the dog. Journal of Bone and Joint Surgery, American Volume. ,vol. 75, pp. 1795- 1803 ,(1993) , 10.2106/00004623-199312000-00009
Andreas Weiler, Henning J. Windhagen, Michael J. Raschke, Andrea Laumeyer, Reinhard F. G. Hoffmann, Biodegradable Interference Screw Fixation Exhibits Pull-Out Force and Stiffness Similar to Titanium Screws: American Journal of Sports Medicine. ,vol. 26, pp. 119- 128 ,(1998) , 10.1177/03635465980260010401
Patrick E. Greis, Robert T. Burks, Kent Bachus, Mark G. Luker, The influence of tendon length and fit on the strength of a tendon-bone tunnel complex. A biomechanical and histologic study in the dog. American Journal of Sports Medicine. ,vol. 29, pp. 493- 497 ,(2001) , 10.1177/03635465010290041901