Validity of the uniform mixing assumption: determining human exposure to environmental tobacco smoke.

作者: N E Klepeis

DOI: 10.1289/EHP.99107S2357

关键词:

摘要: When using the mass balance equation to model indoor air quality, primary assumption is that of uniform mixing. Different points in a single compartment are assumed have same instantaneous pollutant concentrations as all other points. Although such an may be unrealistic, under certain conditions predictions (or measurements) exposures at room still within acceptable limits error (e.g., 10%). In this article, three studies mixing environmental tobacco smoke (ETS) pollutants reviewed, and data from several ETS field presented. Under typical for both short sources 10 min) continuous smoking lounges, I find average exposure point represent across 10% averaging times ranging 12 80 min. present method determining theoretical estimates source.

参考文章(11)
Edwin J. Furtaw, Jr., Muhilan D. Pandian, Dwayne R. Nelson, Joseph V. Behar, Modeling indoor air concentrations near emission sources in imperfectly mixed rooms. Journal of The Air & Waste Management Association. ,vol. 46, pp. 861- 868 ,(1996) , 10.1080/10473289.1996.10467522
Neil E. Klepeis, Wayne R. Ott, Paul Switzer, A Multiple-Smoker Model for Predicting Indoor Air Quality in Public Lounges Environmental Science & Technology. ,vol. 30, pp. 2813- 2820 ,(1996) , 10.1021/ES960067F
W R Ott, Mathematical models for predicting indoor air quality from smoking activity. Environmental Health Perspectives. ,vol. 107, pp. 375- 381 ,(1999) , 10.1289/EHP.99107S2375
F. Haghighat, Z. Jiang, J. C. Y. Wang, F. Allard, Air Movement in Buildings Using Computational Fluid Dynamics Journal of Solar Energy Engineering. ,vol. 114, pp. 84- 92 ,(1992) , 10.1115/1.2929994
A. V. Baughman, A. J. Gadgil, W. W. Nazaroff, Mixing of a Point Source Pollutant by Natural Convection Flow within a Room Indoor Air. ,vol. 4, pp. 114- 122 ,(1994) , 10.1111/J.1600-0668.1994.T01-2-00006.X
Wayne Ott, Paul Switzer, John Robinson, Particle Concentrations Inside a Tavern Before and After Prohibition of Smoking: Evaluating the Performance of an Indoor Air Quality Model Journal of The Air & Waste Management Association. ,vol. 46, pp. 1120- 1134 ,(1996) , 10.1080/10473289.1996.10467548
A. C. Drescher, C. Lobascio, A. J. Gadgil, W. W. Nazarofif, Mixing of a Point‐Source Indoor Pollutant by Forced Convection Indoor Air. ,vol. 5, pp. 204- 214 ,(1995) , 10.1111/J.1600-0668.1995.T01-1-00007.X
L Langan, W R Ott, P Switzer, TIME SERIES MODEL FOR CIGARETTE SMOKING ACTIVITY PATTERNS: MODEL VALIDATION FOR CARBON MONOXIDE AND RESPIRABLE PARTICLES IN A CHAMBER AND AN AUTOMOBILE JOURNAL OF EXPOSURE ANALYSIS AND ENVIRONMENTAL EPIDEMIOLOGY. ,vol. 2, pp. 175- 200 ,(1992)