Determination of trace chromium(VI) by an inhibition-based enzyme biosensor incorporating an electropolymerized aniline membrane and ferrocene as electron transfer mediator

作者: Guang-Ming Zeng , Lin Tang , Guo-Li Shen , Guo-He Huang , Cheng-Gang Niu

DOI: 10.1080/03067310410001730619

关键词:

摘要: A novel inhibition-based glucose oxidase (GOx) biosensor for environmental chromium(VI) detection is described. An electropolymerized aniline membrane has been prepared on a platinum electrode containing ferrocene as electron transfer mediator, which GOx cross-linked by glutaraldehyde. The mechanism of the redox reaction and performance sensor are studied. sensor's response to decreases when it inhibited chromium(VI), with lower limit 0.49 µg L−1, linear range divided into two parts, one 0.49–95.73 µg L−1 other 95.73 µg−1 to8.05 mg L−1. enzyme shown be completely reactivated after inhibition, retaining 90% activity over more than forty days. Interference determination from lead(II), copper(II), cadmium(II), chromium(III), cobalt(II), tin(II) nickel(II) found minimal, while high concentrations mercury(II) silver(I) may interfere determ...

参考文章(21)
Harold J. Bright, David J.T. Porter, 7 Flavoprotein Oxidases The Enzymes. ,vol. 12, pp. 421- 505 ,(1975) , 10.1016/S1874-6047(08)60230-9
R Garjonyte, A Malinauskas, Amperometric glucose biosensor based on glucose oxidase immobilized in poly(o-phenylenediamine) layer Sensors and Actuators B-chemical. ,vol. 56, pp. 85- 92 ,(1999) , 10.1016/S0925-4005(99)00163-X
Joseph Wang, Amperometric biosensors for clinical and therapeutic drug monitoring: a review. Journal of Pharmaceutical and Biomedical Analysis. ,vol. 19, pp. 47- 53 ,(1999) , 10.1016/S0731-7085(98)00056-9
Emrah Kilinc, Mehmet Ozsoz, Omowunmi A. Sadik, Electrochemical Detection of NO by Inhibition on Oxidase Activity Electroanalysis. ,vol. 12, pp. 1467- 1471 ,(2000) , 10.1002/1521-4109(200012)12:18<1467::AID-ELAN1467>3.0.CO;2-9
Hye-Sung Lee, Young-Ah Kim, Duck Hwa Chung, Yong Tae Lee, Determination of carbamate pesticides by a cholinesterase‐based flow injection biosensor International Journal of Food Science and Technology. ,vol. 36, pp. 263- 269 ,(2001) , 10.1046/J.1365-2621.2001.00453.X
V VOLOTOVSKY, N KIM, Cyanide determination by an ISFET-based peroxidase biosensor. Biosensors and Bioelectronics. ,vol. 13, pp. 1029- 1033 ,(1998) , 10.1016/S0956-5663(98)00004-9
Wen-June Cho, Hsuan-Jung Huang, An Amperometric Urea Biosensor Based on a Polyaniline−Perfluorosulfonated Ionomer Composite Electrode Analytical Chemistry. ,vol. 70, pp. 3946- 3951 ,(1998) , 10.1021/AC980004A