Navigation-assisted transsphenoidal deflation of a detachable balloon in the cavernous sinus after embolization of a direct carotid-cavernous fistula

作者: J. Y. Jung , S. H. Kim , D. J. Kim , D.-I. Kim

DOI: 10.1007/S00701-006-1072-2

关键词:

摘要: We describe a case of transsphenoidal deflation detachable balloon after embolization carotid-cavernous fistula (CCF). The patient developed complete third and sixth nerve palsies immediately the CCF, which was considered to be caused by cavernous sinus (CS) compression over-inflated balloon. performed direct puncture via route using frameless neuronavigation system. Navigation-assisted approach (TSA) is technically feasible for in cases severe cranial due an

参考文章(24)
Keith H. Langford, Jiri J. Vitek, Evan Zeiger, Migration of detachable mini-balloon from the ICA causing occlusion of the MCA. Case report. Journal of Neurosurgery. ,vol. 58, pp. 430- 434 ,(1983) , 10.3171/JNS.1983.58.3.0430
Jörg Schipper, Joachim Klisch, Martin Schumacher, Hartmut Husstedt, Roland Laszig, Transsphenoidal computer-navigation-assisted deflation of a balloon after endovascular occlusion of a direct carotid cavernous sinus fistula. American Journal of Neuroradiology. ,vol. 22, pp. 537- 540 ,(2001)
Chao-Bao Luo, Michael Mu-Huo Teng, David Hung-Tsang Yen, Feng-Chi Chang, Jiing-Feng Lirng, Cheng-Yen Chang, Endovascular embolization of recurrent traumatic carotid-cavernous fistulas managed previously with detachable balloons Journal of Trauma-injury Infection and Critical Care. ,vol. 56, pp. 1214- 1220 ,(2004) , 10.1097/01.TA.0000131213.93205.57
Gerard M. Debrun, Fernando Viñuela, Allan J. Fox, Kenneth R. Davis, Hyo S. Ahn, Indications for treatment and classification of 132 carotid-cavernous fistulas. Neurosurgery. ,vol. 22, pp. 285- 289 ,(1988) , 10.1227/00006123-198802000-00001
RT Higashida, VV Halbach, FY Tsai, D Norman, HF Pribram, CM Mehringer, GB Hieshima, Interventional neurovascular treatment of traumatic carotid and vertebral artery lesions: results in 234 cases. American Journal of Roentgenology. ,vol. 153, pp. 577- 582 ,(1989) , 10.2214/AJR.153.3.577
Daniel L. Barrow, Alan S. Fleischer, James C. Hoffman, Complications of detachable balloon catheter technique in the treatment of traumatic intracranial arteriovenous fistulas. Journal of Neurosurgery. ,vol. 56, pp. 396- 403 ,(1982) , 10.3171/JNS.1982.56.3.0396
M M Teng, J F Lirng, T Chang, S S Chen, W Y Guo, C C Cheng, W C Shen, L S Lee, Embolization of carotid cavernous fistula by means of direct puncture through the superior orbital fissure. Radiology. ,vol. 194, pp. 705- 711 ,(1995) , 10.1148/RADIOLOGY.194.3.7862966
H. Hunt Batjer, Phillip D. Purdy, Melissa Neiman, Duke S. Samson, Subtemporal transdural use of detachable balloons for traumatic carotid-cavernous fistulas. Neurosurgery. ,vol. 22, pp. 290- 296 ,(1988) , 10.1227/00006123-198802000-00002