Harmonic emission of household devices in presence of typical voltage distortions

作者: Sergey Yanchenko , Jan Meyer

DOI: 10.1109/PTC.2015.7232518

关键词:

摘要: The level of harmonic currents emitted by nonlinear household devices depends on many factors. Beside the general circuit topology, e.g. presence or absence power factor correction (PFC) emission significantly distortion supply voltage. paper discusses typical voltage distortions in public low grids and proposes parameters for their quantification. Afterwards, Simulink-based time-domain models some electronic are introduced verified measurement data. Finally, impact waveform both individual aggregate loads is assessed, order to compare current distorted sinusoidal voltages.

参考文章(8)
Marc Doebroenti, Markus Schmid, Thomas Duerbaum, Matlab based fast and accurate simulation of a power factor corrector switch-mode power supply in boundary conduction mode with valley skipping workshop on control and modeling for power electronics. pp. 1- 8 ,(2010) , 10.1109/COMPEL.2010.5562417
Sergey Yanchenko, Peter Schegner, Jan Meyer, Ana María Blanco Castañeda, Impact of Supply Voltage Distortion on the Harmonic Emission of Electronic Household Equipment Simposio Internacional sobre la Calidad de la Energía Eléctrica - SICEL. ,vol. 7, pp. 8- ,(2013)
K. De Gusseme, D.M. Van de Sype, A.P. Van den Bossche, J.A. Melkebeek, Input current distortion of CCM boost PFC converters operated in DCM ieee annual conference on power electronics specialist. ,vol. 4, pp. 1685- 1690 ,(2003) , 10.1109/PESC.2003.1217710
A. Mansoor, W.M. Grady, R.S. Thallam, M.T. Doyle, S.D. Krein, M.J. Samotyj, Effect of supply voltage harmonics on the input current of single-phase diode bridge rectifier loads IEEE Transactions on Power Delivery. ,vol. 10, pp. 1416- 1422 ,(1995) , 10.1109/61.400924
N.R. Watson, T.L. Scott, S. Hirsch, Implications for Distribution Networks of High Penetration of Compact Fluorescent Lamps IEEE Transactions on Power Delivery. ,vol. 24, pp. 1521- 1528 ,(2009) , 10.1109/TPWRD.2009.2014036
Koen De Gusseme, David M. Van de Sype, Alex P. M. Van den Bossche, Jan A. Melkebeek, Input-Current Distortion of CCM Boost PFC Converters Operated in DCM IEEE Transactions on Industrial Electronics. ,vol. 54, pp. 858- 865 ,(2007) , 10.1109/TIE.2007.892252
A.J. Collin, J.L. Acosta, B.P. Hayes, S.Z. Djokic, Component-based aggregate load models for combined power flow and harmonic analysis Power Generation, Transmission, Distribution and Energy Conversion (MedPower 2010), 7th Mediterranean Conference and Exhibition on. pp. 1- 10 ,(2010) , 10.1049/CP.2010.0901