Locking plate fixation for Vancouver B1 periprosthetic femoral fractures: a critical analysis of 135 cases

作者: Simon M. Graham , Mehran Moazen , Andreas Leonidou , Eleftherios Tsiridis

DOI: 10.1007/S00776-013-0359-4

关键词:

摘要: Purpose The overall incidence of periprosthetic femoral fractures (PPF) is between 0.1 and 6 % all total hip arthroplasties. Locking compression plates (LCP) have been used for the treatment Vancouver B1 PPFs with variable results. The aim this study to examine literature on locking plate failure rates, mode reasons failure.

参考文章(31)
S. M. Perren, EVOLUTION OF THE INTERNAL FIXATION OF LONG BONE FRACTURES Journal of Bone and Joint Surgery-british Volume. pp. 1093- 1110 ,(2002) , 10.1302/0301-620X.84B8.0841093
W. M. Ricci, B. R. Bolhofner, T. Loftus, C. Cox, S. Mitchell, J. Borrelli, Indirect Reduction and Plate Fixation, Without Grafting, for Periprosthetic Femoral Shaft Fractures About a Stable Intramedullary Implant: Surgical Technique Journal of Bone and Joint Surgery, American Volume. ,vol. 88, pp. 275- 282 ,(2006) , 10.2106/JBJS.F.00327
B A Masri, C P Duncan, Fractures of the femur after hip replacement. Journal of Bone and Joint Surgery, American Volume. ,vol. 44, pp. 293- 304 ,(1995)
Eleftherios Tsiridis, George Pavlou, Ram Venkatesh, Peter Bobak, Graham Gie, Periprosthetic femoral fractures around hip arthroplasty: current concepts in their management. Hip International. ,vol. 19, pp. 75- 86 ,(2009) , 10.1177/112070000901900201
Daniel J. Berry, Epidemiology: hip and knee. Orthopedic Clinics of North America. ,vol. 30, pp. 183- 190 ,(1999) , 10.1016/S0030-5898(05)70073-0
Jagannath Chakravarthy, Rajeev Bansal, Julian Cooper, Locking plate osteosynthesis for Vancouver Type B1 and Type C periprosthetic fractures of femur: a report on 12 patients. Injury-international Journal of The Care of The Injured. ,vol. 38, pp. 725- 733 ,(2007) , 10.1016/J.INJURY.2007.02.038
Mohamed Khalid, Kanthan Theivendran, Mubashir Cheema, Vaikunthan Rajaratnam, Subodh C Deshmukh, None, Biomechanical comparison of pull-out force of unicortical versus bicortical screws in proximal phalanges of the hand: a human cadaveric study. Clinical Biomechanics. ,vol. 23, pp. 1136- 1140 ,(2008) , 10.1016/J.CLINBIOMECH.2008.06.005
M. Ahmad, R. Nanda, A.S. Bajwa, J. Candal-Couto, S. Green, A.C. Hui, Biomechanical testing of the locking compression plate: When does the distance between bone and implant significantly reduce construct stability? Injury-international Journal of The Care of The Injured. ,vol. 38, pp. 358- 364 ,(2007) , 10.1016/J.INJURY.2006.08.058
R.E. Anakwe, S.A. Aitken, L.A.K. Khan, Osteoporotic periprosthetic fractures of the femur in elderly patients: outcome after fixation with the LISS plate. Injury-international Journal of The Care of The Injured. ,vol. 39, pp. 1191- 1197 ,(2008) , 10.1016/J.INJURY.2008.02.003