Trapping parameters from isothermal decay of TL

作者: S V Moharil

DOI: 10.1088/0022-3727/14/9/016

关键词:

摘要: Most of the existing methods for obtaining frequency factors make use trap depth, or some assumption regarding order kinetics. This introduces arbitration, as E values obtained using various differ appreciably. is one reasons inconsistencies in reported trapping parameters. A method independent depth needed. Such a method, making isothermal decay TL, presented.

参考文章(6)
S P Kathuria, C M Sunta, Kinetics and trapping parameters of thermoluminescence in LiF TLD-100-dependence on dose Journal of Physics D. ,vol. 12, pp. 1573- 1587 ,(1979) , 10.1088/0022-3727/12/9/020
C. E. May, J. A. Partridge, Thermoluminescent Kinetics of Alpha‐Irradiated Alkali Halides The Journal of Chemical Physics. ,vol. 40, pp. 1401- 1409 ,(1964) , 10.1063/1.1725324
C. S. Shalgaonkar, A. V. Narlikar, Review: a review of the recent methods for determining trap depth from glow curves Journal of Materials Science. ,vol. 7, pp. 1465- 1471 ,(1972) , 10.1007/BF00574938
G C Taylor, E Lilley, The analysis of thermoluminescent glow peaks in LiF (TLD-100) Journal of Physics D. ,vol. 11, pp. 567- 581 ,(1978) , 10.1088/0022-3727/11/4/020
M. Antinucci, M. Cevolani, G. C. Degli Esposti, S. Petralia, An analysis of the thermoluminescent peaks of LiF (TLD 100) Lettere Al Nuovo Cimento. ,vol. 18, pp. 393- 399 ,(1977) , 10.1007/BF02782601