Impedance cardiography: more questions than answers.

作者: David J. Wang , Stephen S. Gottlieb

DOI: 10.1007/S11897-006-0009-7

关键词:

摘要: Thoracic electrical bioimpedance, also known as impedance cardiography (ICG), is a noninvasive method to obtain hemodynamic measurements, including cardiac output. Recently, there has been flurry of reports on the clinical use ICG. Authors have suggested that ICG measurements are useful for myriad situations, diagnosis heart failure, monitoring patient’s status, and assisting in medicine titration decisions. However, data continue suggest poor correlation between current generation devices invasive output, especially failure patients. not able accurately measure left ventricular filling pressures. There limited demonstrating any improved outcomes using setting. Given available data, should be research

参考文章(49)
R P Patterson, R H Mattson, D A Witsoe, J N Karnegis, W G Kubicek, Development and evaluation of an impedance cardiac output system Aerospace medicine. ,vol. 37, pp. 1208- 1212 ,(1966)
Nancy M. Albert, Melanie D. Hail, Jianbo Li, James B. Young, Equivalence of the Bioimpedance and Thermodilution Methods in Measuring Cardiac Output in Hospitalized Patients With Advanced, Decompensated Chronic Heart Failure American Journal of Critical Care. ,vol. 13, pp. 469- 479 ,(2004) , 10.4037/AJCC2004.13.6.469
Paulo Cesar Campos, Ivan A. D’Cruz, Lillie S. Johnson, Amit Malhotra, Kodangudi B. Ramanathan, Karl T. Weber, Functional valvular incompetence in decompensated heart failure: noninvasive monitoring and response to medical management. The American Journal of the Medical Sciences. ,vol. 329, pp. 217- 221 ,(2005) , 10.1097/00000441-200505000-00001
A ABDELHAMMED, R SMITH, P LEVY, G SMITS, C FERRARIO, Noninvasive hemodynamic profiles in hypertensive subjects. American Journal of Hypertension. ,vol. 18, pp. 51- 59 ,(2005) , 10.1016/J.AMJHYPER.2004.11.043
Charles L Springfield, Frank Sebat, David Johnson, Steven Lengle, Christian Sebat, None, Utility of Impedance Cardiography to Determine Cardiac vs. Noncardiac Cause of Dyspnea in the Emergency Department Congestive Heart Failure. ,vol. 10, pp. 14- 16 ,(2004) , 10.1111/J.1527-5299.2004.03409.X
Marjorie Funk, Karin V. Nystrom, Charmaine Hutchinson, Stuart D. Katz, Forrester A. Lee, Bioimpedance monitoring in patients with chronic heart failure Journal of Cardiac Failure. ,vol. 9, ,(2003) , 10.1016/S1071-9164(03)00177-5
Esther Raaijmakers, Theo J. C. Faes, Rob J. P. M. Scholten, Henk G. Goovaerts, Rob M. Heethaar, A meta-analysis of three decades of validating thoracic impedance cardiography. Critical Care Medicine. ,vol. 27, pp. 1203- 1213 ,(1999) , 10.1097/00003246-199906000-00053
C. JEWKES, J.W. SEAR, F. VERHOEFF, D.J. SANDERS, P. FOËX, NON-INVASIVE MEASUREMENT OF CARDIAC OUTPUT BY THORACIC ELECTRICAL BIOIMPEDANCE: A STUDY OF REPRODUCIBILITY AND COMPARISON WITH THERMODILUTION BJA: British Journal of Anaesthesia. ,vol. 67, pp. 788- 794 ,(1991) , 10.1093/BJA/67.6.788
Barry H. Greenberg, Denise D. Hermann, Maryann F. Pranulis, Lucia Lazio, David Cloutier, Reproducibility of Impedance Cardiography Hemodynamic Measures in Clinically Stable Heart Failure Patients Congestive Heart Failure. ,vol. 6, pp. 74- 82 ,(2000) , 10.1111/J.1527-5299.2000.80140.X
W.Scott Sageman, Robert H. Riffenburgh, Bruce D. Spiess, Equivalence of bioimpedance and thermodilution in measuring cardiac index after cardiac surgery. Journal of Cardiothoracic and Vascular Anesthesia. ,vol. 16, pp. 8- 14 ,(2002) , 10.1053/JCAN.2002.29635