Sequential determination of actinide isotopes and radiostrontium in swipe samples

作者: Xiongxin Dai , Sheila Kramer-Tremblay

DOI: 10.1007/S10967-011-1096-9

关键词:

摘要: Assays of alpha- and beta-emitting radionuclides in swipe samples are often required to monitor the presence removable surface contamination for radiological protection control nuclear facilities. Swipe analysis has also proven be a very sensitive analytical technique detect signatures safeguard verification purposes. A new sequential method determination actinide isotopes radiostrontium samples, which utilizes streamlined column separation with stacked anion extraction chromatography resins, been developed. To validate procedure, spike blank were prepared analyzed by inductively coupled mass spectrometry (ICP-MS), alpha liquid scintillation (LS) counting. Low detection limits have achieved isotopic Pu (238Pu, 239Pu, 240Pu, 241Pu), U (234U, 235U, 238U), Am (241Am), Cm (242Cm, 243/244Cm) Sr (90Sr) at ultra-trace concentration levels samples.

参考文章(20)
A. Komosa, St. Chibowsk, Determination of plutonium in ground-level air aerosols collected on Petrianov filters Journal of Radioanalytical and Nuclear Chemistry. ,vol. 251, pp. 113- 117 ,(2002) , 10.1023/A:1015006613927
Jeng-Jong Wang, Ing-Jane Chen, Jih-Hung Chiu, Sequential isotopic determination of plutonium, thorium, americium, strontium and uranium in environmental and bioassay samples. Applied Radiation and Isotopes. ,vol. 61, pp. 299- 305 ,(2004) , 10.1016/J.APRADISO.2004.03.025
Xiongxin Dai, Sheila Kramer-Tremblay, AN EMERGENCY BIOASSAY METHOD FOR ACTINIDES IN URINE Health Physics. ,vol. 101, pp. 144- 147 ,(2011) , 10.1097/HP.0B013E318213D006
Narayani P. Singh, McDonald E. Wrenn, Determinations of actinides in biological and environmental samples Science of The Total Environment. ,vol. 70, pp. 187- 203 ,(1988) , 10.1016/0048-9697(88)90259-8
Masaaki MAGARA, Takaaki SAKAKIBARA, Setsumi KUROSAWA, Masato TAKAHASHI, Satoshi SAKURAI, Yukiko HANZAWA, Fumitaka ESAKA, Kazuo WATANABE, Shigekazu USUDA, Isotope ratio measurement of uranium in safeguards environmental samples by inductively-coupled plasma mass spectrometry (ICP-MS) Journal of Nuclear Science and Technology. ,vol. 39, pp. 308- 311 ,(2002) , 10.1080/18811248.2002.9715193
Sherrod L. Maxwell, Brian K. Culligan, Gary W. Noyes, Rapid separation of actinides and radiostrontium in vegetation samples Journal of Radioanalytical and Nuclear Chemistry. ,vol. 286, pp. 273- 282 ,(2010) , 10.1007/S10967-010-0653-Y
S. L. Maxwell, D. M. Faison, Rapid column extraction method for actinides and strontium in fish and other animal tissue samples Journal of Radioanalytical and Nuclear Chemistry. ,vol. 275, pp. 605- 612 ,(2008) , 10.1007/S10967-007-7120-4
S. L. Maxwell III, B. K. Culligan, Rapid column extraction method for actinides in soil Journal of Radioanalytical and Nuclear Chemistry. ,vol. 270, pp. 699- 704 ,(2006) , 10.1007/S10967-006-0449-2