Reversibility of membrane performance and structure changes caused by extreme cold water temperature and elevated conditioning water temperature

作者: Adrianna Tikka , Wa Gao , Baoqiang Liao

DOI: 10.1016/J.WATRES.2018.12.047

关键词:

摘要: Abstract The effects of extreme cold water temperature, elevated cleaning time on membrane performance, and pore size distribution were studied using flat-sheet polyvinylidene fluoride (PVDF) membranes. Extreme temperature led to a decrease in permeability, shrinkage. use periodical warm (35 °C) conditioning could almost completely recover the permeability structure loss caused by while room (23±1 °C) recovered majority temperature. Changes performance correlate well with changes structure. Membranes periodically conditioned warmer showed higher than that at from long-term operation three months. results suggest change PVDF is reversible after conditioning, thus and/or chemical will benefit recovery regions.

参考文章(25)
Khosrow Farahbakhsh, Daniel W Smith, Membrane filtration for cold regions – impact of cold water on membrane integrity monitoring tests Journal of Environmental Engineering and Science. ,vol. 5, pp. S69- S75 ,(2006) , 10.1139/S06-037
Yu Xia, Xia Huang, David Waite, Jing Guan, Zhun Ma, Xianghua Wen, Fang Zhao, Effect of temperature variation on membrane fouling and microbial community structure in membrane bioreactor Bioresource Technology. ,vol. 133, pp. 462- 468 ,(2013) , 10.1016/J.BIORTECH.2013.01.023
Chiqian Zhang, Guangzhi Wang, Zhiqiang Hu, Changes in wastewater treatment performance and activated sludge properties of a membrane bioreactor at low temperature operation. Environmental Science: Processes & Impacts. ,vol. 16, pp. 2199- 2207 ,(2014) , 10.1039/C4EM00174E
Hai Quang Dang, William E. Price, Long Duc Nghiem, The effects of feed solution temperature on pore size and trace organic contaminant rejection by the nanofiltration membrane NF270 Separation and Purification Technology. ,vol. 125, pp. 43- 51 ,(2014) , 10.1016/J.SEPPUR.2013.12.043
Syed Z Abdullah, Pierre R Bérubé, None, Assessing the effects of sodium hypochlorite exposure on the characteristics of PVDF based membranes. Water Research. ,vol. 47, pp. 5392- 5399 ,(2013) , 10.1016/J.WATRES.2013.06.018
Isabelle Masselin, Xavier Chasseray, Laurence Durand-Bourlier, Jean-Michel Lainé, Pierre-Yves Syzaret, Daniel Lemordant, None, Effect of sonication on polymeric membranes Journal of Membrane Science. ,vol. 181, pp. 213- 220 ,(2001) , 10.1016/S0376-7388(00)00534-2
Ramesh R. Sharma, Shankararaman Chellam, Temperature effects on the morphology of porous thin film composite nanofiltration membranes. Environmental Science & Technology. ,vol. 39, pp. 5022- 5030 ,(2005) , 10.1021/ES0501363
P. Krzeminski, A. Iglesias-Obelleiro, G. Madebo, J.M. Garrido, J.H.J.M. van der Graaf, J.B. van Lier, Impact of temperature on raw wastewater composition and activated sludge filterability in full-scale MBR systems for municipal sewage treatment Journal of Membrane Science. ,vol. 423, pp. 348- 361 ,(2012) , 10.1016/J.MEMSCI.2012.08.032