Use of a silicon microsensor for pressure monitoring inside the wound and outcomes on healing.

作者: J. Mejzlik

DOI: 10.12968/JOWC.2012.21.12.589

关键词:

摘要: • Objective: To ascertain the extent to which pressure within a defined neck compartment could be used as predictor for wound healing. Method: Thirty patients with various head and malignancies that were treated surgically, considered prospectively. In course of surgery microsensor was implanted into data collected over first 48 hours postoperatively. logistic regression analysis determine strength interfascial (IP) Results: Mean IP 7.45 ± 6.15mmHg (95%Cl 7.13; 7.77). A model relating good/disturbed healing outcome revealed mean is key variable, major influence on outcome. However, this type only explains approximately 46% total variation in responses. This implies, although change contributes significantly explaining variations healing, there may other significant predictor...

参考文章(12)
E. Arató, M. Kürthy, L. Sínay, G. Kasza, G. Menyhei, S. Masoud, A. Bertalan, Zs. Verzár, L. Kollár, E. Rőth, G. Jancsó, Pathology and diagnostic options of lower limb compartment syndrome Clinical Hemorheology and Microcirculation. ,vol. 41, pp. 1- 8 ,(2009) , 10.3233/CH-2009-1145
J A Shaw, D G Murray, The relationship between tourniquet pressure and underlying soft-tissue pressure in the thigh. The Journal of Bone & Joint Surgery. ,vol. 64, pp. 1148- 1152 ,(1982) , 10.2106/00004623-198264080-00004
Francisco F Pracca, Alberto A Biestro, Leandro Moraes, Corina B Puppo, Stella M Calvo, Jose Gorrasi, Mario Cancela, Direct measurement of intra-abdominal pressure with a solid microtranducer. Journal of Clinical Monitoring and Computing. ,vol. 21, pp. 167- 170 ,(2007) , 10.1007/S10877-007-9071-2
Ana PCP Carlotti, Werther B Carvalho, None, Abdominal compartment syndrome: A review. Pediatric Critical Care Medicine. ,vol. 10, pp. 115- 120 ,(2009) , 10.1097/PCC.0B013E31819371B2
D. F. SIGNORINI, A. SHAD, I. R. PIPER, P. F. X. STATHAM, A clinical evaluation of the Codman MicroSensor for intracranial pressure monitoring. British Journal of Neurosurgery. ,vol. 12, pp. 223- 227 ,(1998) , 10.1080/02688699845032
W. Köstler, P.C. Strohm, N.P. Südkamp, Acute compartment syndrome of the limb Injury. ,vol. 35, pp. 1221- 1227 ,(2004) , 10.1016/J.INJURY.2004.04.009
Mayur M. Amonkar, Benjamin Chastek, Navendu Samant, April Teitelbaum, Economic burden of resected squamous cell carcinoma of the head and neck in a US managed-care population. Journal of Medical Economics. ,vol. 14, pp. 421- 432 ,(2011) , 10.3111/13696998.2011.584096
Frederick A. Matsen, Geoffrey W. Sheridan, Richard B. Krugmire, Keith A. Mayo, Monitoring of intramuscular pressure. Surgery. ,vol. 79, pp. 702- 709 ,(1976) , 10.5555/URI:PII:0039606076902385