摘要: A meander-line grid-array antenna specified by an area-reduction factor η is analysed using the method of moments. The fed from a coaxial line (unbalanced feed) located near centre. gain close to value roughly estimated Gref + 10 log10 (1 – η) dBi, where reference composed straight wires. It found that contributes controlling HPBW in H-plane, keeping E-plane constant. frequency responses input impedance and are also presented for = 0 38% with experimental results.