Comparison of electrical, thermal, and pulse oximetry methods for assessing pulp vitality in recently traumatized teeth.

作者: Velayutham Gopikrishna , Kush Tinagupta , Deivanayagam Kandaswamy

DOI: 10.1016/J.JOEN.2007.01.014

关键词:

摘要: Pulse oximeter is a well-established and noninvasive method for measuring vascular health by evaluating oxygen saturation. This study compared the efficacy of custom-made pulse dental probe with electric pulp testing thermal vitality status recently traumatized permanent teeth. Readings 17 maxillary incisors were taken (group 1), electrical tester 2), 3) over 6-month period. The proportion teeth showing positive responsiveness in thermal/electric tests increased from no on day 0 to 29.4% 28th day, 82.35% at 2 months, 94.11% 3 months. However, gave readings that remained constant period 6 months all patients.

参考文章(24)
J M Mumford, Thermal and electrical stimulation of teeth in the diagnosis of pulpal and periapical disease. Journal of the Royal Society of Medicine. ,vol. 60, pp. 197- 200 ,(1967) , 10.1177/003591576706000239
B Hedegård, I Stålhane, Traumatized permanent teeth in children aged 7-15 years. Svensk tandlakare tidskrift. Swedish dental journal. ,vol. 68, pp. 157- 169 ,(1975)
Jens O. Andreasen, Frances M. Andreasen, Lars Andersson, Textbook and Color Atlas of Traumatic Injuries to the Teeth ,(1994)
J.J. RAVN, Follow of permanent incisors with enamel cracks as a result of an acute trauma European Journal of Oral Sciences. ,vol. 89, pp. 117- 123 ,(1981) , 10.1111/J.1600-0722.1981.TB01661.X
Frances M. Andreasen, Bo Vestergaard Pedersen, Prognosis of luxated permanent teeth — the development of pulp necrosis Endodontics & Dental Traumatology. ,vol. 1, pp. 207- 220 ,(1985) , 10.1111/J.1600-9657.1985.TB00583.X
Zvi Fuss, Henry Trowbridge, I.B. Bender, Bruce Rickoff, Solomon Sorin, Assessment of reliability of electrical and thermal pulp testing agents Journal of Endodontics. ,vol. 12, pp. 301- 305 ,(1986) , 10.1016/S0099-2399(86)80112-1
Velayutham Gopikrishna, Kush Tinagupta, Deivanayagam Kandaswamy, Evaluation of Efficacy of a New Custom-Made Pulse Oximeter Dental Probe in Comparison With the Electrical and Thermal Tests for Assessing Pulp Vitality Journal of Endodontics. ,vol. 33, pp. 411- 414 ,(2007) , 10.1016/J.JOEN.2006.12.003
V Gopi Krishna, D Kandaswamy, T Gupta, Assessment of the efficacy of an indigeniously developed pulse oximeter dental sensor holder for pulp vitality testing. Indian Journal of Dental Research. ,vol. 17, pp. 111- 113 ,(2006) , 10.4103/0970-9290.29880
Richard S. Kahan, Kishor Gulabivala, Martin Snook, Derrick J. Setchell, Evaluation of a pulse oximeter and customized probe for pulp vitality testing Journal of Endodontics. ,vol. 22, pp. 105- 109 ,(1996) , 10.1016/S0099-2399(96)80283-4