Wind loads on wind permeable facades

作者: H.J. Gerhardt , F. Janser

DOI: 10.1016/0167-6105(94)90017-5

关键词:

摘要: Abstract This paper presents results of a fundamental, experimental study on wind loading porous facade systems. The important parameters — relative building dimensions, porosity, and gap width have been varied systematically in model scale study. Both time averaged fluctuating pressures measured. Therefore, loads using the quasi-static approach peak pressure may be derived. validity investigation has checked by full experiments.

参考文章(7)
A G DAVENPORT, THE APPLICATION OF STATISTICAL CONCEPTS TO THE WIND LOADING OF STRUCTURES. Proceedings of the Institution of Civil Engineers. ,vol. 19, pp. 449- 472 ,(1961) , 10.1680/IICEP.1961.11304
H.J. Gerhardt, C. Kramer, Wind loads on wind-permeable building facades Journal of Wind Engineering and Industrial Aerodynamics. ,vol. 11, pp. 1- 20 ,(1983) , 10.1016/0167-6105(83)90087-9
H.J. Gerhardt, C. Kramer, K.K. Bofah, Wind loading on loosely laid pavers and insulation boards for flat roofs Journal of Wind Engineering and Industrial Aerodynamics. ,vol. 36, pp. 309- 318 ,(1990) , 10.1016/0167-6105(90)90315-4
C. Kramer, H. J. Gerhardt, Windkräfte an hinterlüfteten Fassaden Betonwerk + Fertigteil-Technik. ,vol. 51, pp. 46- 53 ,(1985)
T.A. Wyatt, The designer's guide to wind loading of building structures. Part 2: Static structures Journal of Constructional Steel Research. ,vol. 17, pp. 259- 260 ,(1990) , 10.1016/0143-974X(90)90060-T
Nicholas John Cook, The designer's guide to wind loading of building structures. Vol.2: Static structures Building Research Establishment Report. ,(1990)