Are electrocardiographic Q-wave criteria reliable for diagnosis of perioperative myocardial infarction after coronary surgery?

作者: Rolf Svedjeholm , Lars Goran Dahlin , Claes Lundberg , Zoltan Szabo , Bertil Kågedal

DOI: 10.1016/S1010-7940(98)00091-8

关键词:

摘要: Objective: A major assumption in cardiovascular medicine is that Q-waves on the electrocardiogram indicate myocardial tissue damage. The appearance of a new Q-wave has therefore been consider ...

参考文章(28)
Ary L. Goldberger, Normal and Noninfarct Q Waves Cardiology Clinics. ,vol. 5, pp. 357- 366 ,(1987) , 10.1016/S0733-8651(18)30526-5
Frederick Van Lente, Amy Martin, Norman B. Ratliff, Steven C. Kazmierczak, Floyd D. Loop, The predictive value of serum enzymes for perioperative myocardial infarction after cardiac operations. An autopsy study. The Journal of Thoracic and Cardiovascular Surgery. ,vol. 98, pp. 704- 710 ,(1989) , 10.1016/S0022-5223(19)34292-8
Valentin Fuster, Robert C. Schlant, R. Wayne Alexander, Hurst's the Heart, Arteries and Veins ,(1998)
H A Katus, S Looser, K Hallermayer, A Remppis, T Scheffold, A Borgya, U Essig, U Geuss, Development and in vitro characterization of a new immunoassay of cardiac troponin T. Clinical Chemistry. ,vol. 38, pp. 386- 393 ,(1992) , 10.1093/CLINCHEM/38.3.386
H.O. Klein, H. Gross, I.L. Rubin, Transient electrocardiographic changes simulating myocardial infarction during open-heart surgery American Heart Journal. ,vol. 79, pp. 463- 470 ,(1970) , 10.1016/0002-8703(70)90251-6
Stephen Slogoff, Arthur S. Keats, Randomized Trial of Primary Anesthetic Agents on Outcome of Coronary Artery Bypass Operations Anesthesiology. ,vol. 70, pp. 179- 188 ,(1989) , 10.1097/00000542-198902000-00002
Randall C. Smith, Jacqueline M. Leung, Dennis T. Mangano, , Postoperative Myocardial Ischemia in Patients Undergoing Coronary Artery Bypass Graft Surgery Anesthesiology. ,vol. 74, pp. 464- 473 ,(1991) , 10.1097/00000542-199103000-00013
W. Gerhardt, L. Ljungdahl, Rational diagnostic strategy in diagnosis of ischemic myocardial injury. S-troponin T and S-CK MB (mass) time series using individual baseline values Scandinavian Journal of Clinical & Laboratory Investigation. ,vol. 53, pp. 47- 59 ,(1993) , 10.3109/00365519309090697
S.Y. Farah, D.W. Moss, P. Ribeiro, Celia M. Oakley, R.N. Sapsford, Interpretation of changes in the activity of creatine kinase MB isoenzyme in serum after coronary artery bypass grafting. Clinica Chimica Acta. ,vol. 141, pp. 219- 225 ,(1984) , 10.1016/0009-8981(84)90013-5
J.D. Woods, W. Laurie, W.G. Smith, The reliability of the electrocardiogram in myocardial infarction. The Lancet. ,vol. 282, pp. 265- 269 ,(1963) , 10.1016/S0140-6736(63)90170-3