Chitosan nanomagnets for effective extraction and sensitive mass spectrometric detection of pathogenic bacterial endotoxin from human urine.

作者: Judy Gopal , Hani Nasser Abdelhamid , Pei-Yang Hua , Hui-Fen Wu

DOI: 10.1039/C3TB20079E

关键词:

摘要: … -free of extraction/detection method for endotoxin in clinical samples (human urine) to show the … We have attempted extraction of LPS from 5, 15, 30 and 50 mL of bacterial suspensions. …

参考文章(77)
E S Stanislavsky, N A Kocharova, N K Kochetkov, B Lányi, Knirel YuA, E V Vinogradov, N A Paramonov, B A Dmitriev, The structure of O-specific polysaccharides and serological classification of Pseudomonas aeruginosa (a review). Acta microbiologica Hungarica. ,vol. 35, pp. 3- 24 ,(1988)
B. Lányi, T. Bergan, Chapter IV Serological Characterization of Pseudomonas aeruginosa Methods in Microbiology. ,vol. 10, pp. 93- 168 ,(1978) , 10.1016/S0580-9517(08)70661-5
Irina Sadovskaya, Jean-Robert Brisson, Pierre Thibault, James C Richards, Joseph S Lam, Eleonora Altman, Structural characterization of the outer core and the O-chain linkage region of lipopolysaccharide from Pseudomonas aeruginosa serotype O5 European Journal of Biochemistry. ,vol. 267, pp. 1640- 1650 ,(2000) , 10.1046/J.1432-1327.2000.01156.X
Hiroshi Nikaido, Taiji Nakae, The Outer Membrane of Gram-negative Bacteria Advances in Microbial Physiology. ,vol. 20, pp. 163- 250 ,(1980) , 10.1016/S0065-2911(08)60208-8
M. Caroff, C. Deprun, D. Karibian, 252Cf plasma desorption mass spectrometry applied to the analysis of underivatized rough-type endotoxin preparations. Journal of Biological Chemistry. ,vol. 268, pp. 12321- 12324 ,(1993) , 10.1016/S0021-9258(18)31392-9
Muthu Manikandan, Hui-Fen Wu, Nazim Hasan, Cell population based mass spectrometry using platinum nanodots for algal and fungal studies Biosensors and Bioelectronics. ,vol. 35, pp. 493- 497 ,(2012) , 10.1016/J.BIOS.2012.03.020
Muthu Manikandan, Nazim Hasan, Hui-Fen Wu, Rapid and direct detection of attomole adenosine triphosphate (ATP) by MALDI-MS using rutile titania chips Analyst. ,vol. 137, pp. 5128- 5134 ,(2012) , 10.1039/C2AN35754B
Donald E. Woods, Barbara H. Iglewski, Toxins of Pseudomonas aeruginosa: New Perspectives Clinical Infectious Diseases. ,vol. 5, ,(1983) , 10.1093/CLINIDS/5.SUPPLEMENT_4.S715
Michael. Karas, Franz. Hillenkamp, Laser desorption ionization of proteins with molecular masses exceeding 10,000 daltons Analytical Chemistry. ,vol. 60, pp. 2299- 2301 ,(1988) , 10.1021/AC00171A028
Inge K. Herrmann, Martin Urner, Samuel Graf, Christoph M. Schumacher, Birgit Roth-Z'graggen, Melanie Hasler, Wendelin J. Stark, Beatrice Beck-Schimmer, Endotoxin removal by magnetic separation-based blood purification. Advanced Healthcare Materials. ,vol. 2, pp. 829- 835 ,(2013) , 10.1002/ADHM.201200358