A comparison of conductive textile-based and silver/silver chloride gel electrodes in exercise electrocardiogram recordings

作者: Vaidotas Marozas , Andrius Petrenas , Saulius Daukantas , Arunas Lukosevicius

DOI: 10.1016/J.JELECTROCARD.2010.12.004

关键词:

摘要: Abstract Background The goal of this study was to compare disposable silver/silver chloride and reusable conductive textile-based electrodes in electrocardiogram (ECG) signal monitoring during physical activity. Materials Methods were produced using thin silver-plated nylon 117/17 2-ply thread (Statex Productions & Vertriebs GmbH, Bremen, Germany) sewed with a sewing machine on chest belt. compared vivo according ECG baseline drift, broadband electrode noise properties, influence area morphology frequency content. Twelve volunteers included study. Results Electroconductive produce significantly more very low band (0-0.67 Hz) not less (0-250 than electrodes. Decreasing textile decreases fidelity registered signals at frequencies. Conclusion Textile having adequate can be used applications only R-R interval monitoring.

参考文章(15)
S. Fuhrhop, S. Lamparth, M. Kirst, G. v. Wagner, J. Ottenbacher, Ambulant ECG Recording with Wet and Dry Electrodes: A Direct Comparison of two Systems Proceedings of the World Congress on Medical Physics and Biomedical Engineering, 7 - 12 September, 2009, Munich, Germany. Ed.: O. Dössel. pp. 305- 307 ,(2009) , 10.1007/978-3-642-03904-1_85
Jonas Pettersson, Galen S. Wagner, Leif Sörnmo, Elin Trägårdh Johansson, Hans Öhlin, Olle Pahlm, High-frequency electrocardiogram as a supplement to standard 12-lead ischemia monitoring during reperfusion therapy of acute inferior myocardial infarction. Journal of Electrocardiology. ,vol. 44, pp. 11- 17 ,(2011) , 10.1016/J.JELECTROCARD.2010.04.006
Ju-Yeoul Baek, Jin-Hee An, Jong-Min Choi, Kwang-Suk Park, Sang-Hoon Lee, Flexible polymeric dry electrodes for the long-term monitoring of ECG Sensors and Actuators A-physical. ,vol. 143, pp. 423- 429 ,(2008) , 10.1016/J.SNA.2007.11.019
P. J. Xu, H. Zhang, X. M. Tao, Textile-structured electrodes for electrocardiogram Textile Progress. ,vol. 40, pp. 183- 213 ,(2008) , 10.1080/00405160802597479
E.P. Scilingo, A. Gemignani, R. Paradiso, N. Taccini, B. Ghelarducci, D. DeRossi, Performance evaluation of sensing fabrics for monitoring physiological and biomechanical variables international conference of the ieee engineering in medicine and biology society. ,vol. 9, pp. 345- 352 ,(2005) , 10.1109/TITB.2005.854506
Merja M. Puurtinen, Satu M. Komulainen, Pasi K. Kauppinen, Jaakko A. V. Malmivuo, Jari A. K. Hyttinen, Measurement of noise and impedance of dry and wet textile electrodes, and textile electrodes with hydrogel international conference of the ieee engineering in medicine and biology society. ,vol. 1, pp. 6012- 6015 ,(2006) , 10.1109/IEMBS.2006.260155
Olle Pahlm, Stephen C. Hammill, Quality improvement in electrocardiogram recording and interpretation. Journal of Electrocardiology. ,vol. 41, pp. 367- 369 ,(2008) , 10.1016/J.JELECTROCARD.2008.06.007
Klaus-Peter Hoffmann, Roman Ruff, Flexible dry surface-electrodes for ECG long-term monitoring international conference of the ieee engineering in medicine and biology society. ,vol. 2007, pp. 5739- 5742 ,(2007) , 10.1109/IEMBS.2007.4353650
C. Pylatiuk, M. Muller-Riederer, A. Kargov, S. Schulz, O. Schill, M. Reischl, G. Bretthauer, Comparison of surface EMG monitoring electrodes for long-term use in rehabilitation device control ieee international conference on rehabilitation robotics. pp. 300- 304 ,(2009) , 10.1109/ICORR.2009.5209576
Elin Trägårdh, Olle Pahlm, Galen S Wagner, Jonas Pettersson, Reduced high-frequency QRS components in patients with ischemic heart disease compared to normal subjects Journal of Electrocardiology. ,vol. 37, pp. 157- 162 ,(2004) , 10.1016/J.JELECTROCARD.2004.02.004