Semi-automated radiotherapy treatment planning with a mathematical model to satisfy treatment goals.

作者: William D. Powlis , Martin D. Altschuler , Yair Censor , E.Loren Buhle

DOI: 10.1016/0360-3016(89)90042-4

关键词:

摘要: Abstract Iterative algorithms can provide a feasible solution, if any exists, to specified treatment goals. Our model subdivides both the patient's cross section into fine grid of points and radiation beam set “pencil” rays. The anatomy, machine parameters, dose limits homogeneity, are all defined. This process subdivision leads large system linear inequalities with solution that provides intensity distribution will deliver prescribed distribution. clinical results from two different be presented contrasted. Once treatment, parameters have been entered, computerized yield an answer in several minutes. Cimmino algorithm also allows “weights” or priority assignments resulting is biased towards fulfilling doses for anatomic regions which were given greater weight. It desirable systematic search possible alternatives complex situations, including 3-dimensional therapy planning (RTTP). method has applied 2-D RTTP, but equally applicable 3-D RTTP minor modifications.

参考文章(18)
R. Van der Laarsed, J. Strackee, Pseudo optimization of radiotherapy treatment planning British Journal of Radiology. ,vol. 49, pp. 450- 457 ,(1976) , 10.1259/0007-1285-49-581-450
Yair Censor, Row-Action Methods for Huge and Sparse Systems and Their Applications Siam Review. ,vol. 23, pp. 444- 466 ,(1981) , 10.1137/1023097
A T Redpath, B L Vickery, D H Wright, A new technique for radiotherapy planning using quadratic programming Physics in Medicine and Biology. ,vol. 21, pp. 781- 791 ,(1976) , 10.1088/0031-9155/21/5/007
C S Hope, Jean Laurie, J S Orr, K E Halnan, Optimization of x-ray treatment planning by computer judgement. Physics in Medicine and Biology. ,vol. 12, pp. 531- 542 ,(1967) , 10.1088/0031-9155/12/4/310
Mark Langer, Joseph Leong, Optimization of beam weights under dose-volume restrictions. International Journal of Radiation Oncology Biology Physics. ,vol. 13, pp. 1255- 1260 ,(1987) , 10.1016/0360-3016(87)90203-3
Anthony B. Wolbarst, Lee M. Chin, Göran K. Svensson, Optimization of radiation therapy: integral-response of a model biological system. International Journal of Radiation Oncology Biology Physics. ,vol. 8, pp. 1761- 1769 ,(1982) , 10.1016/0360-3016(82)90299-1
Stanley C. McDonald, Philip Rubin, Optimization of external beam radiation therapy International Journal of Radiation Oncology Biology Physics. ,vol. 2, pp. 307- 317 ,(1977) , 10.1016/0360-3016(77)90089-X
J Legras, B Legras, J P Lambert, P Alleti, The use of a microcomputer for non-linear optimisation of doses in external radiotherapy Physics in Medicine and Biology. ,vol. 31, pp. 1353- 1359 ,(1986) , 10.1088/0031-9155/31/12/004