作者: Shan He , Dao Zhou , Xiongfei Wang , Frede Blaabjerg
DOI:
关键词:
摘要: Control delay plays an important role in the stability of grid-connected voltage source converters (VSCs), and the critical value is one quarter of switching period (0.25T sw ) based on the passivity-based stability theory. However, the control delay is 1.5T sw and 0.75T sw for the regular single-sampling and double-sampling pulse width modulation (PWM), respectively, and there will be a large non-dissipative region in the high-frequency range. To tackle this challenge, an enhanced real-time-update PWM is proposed and the control delay can be kept to 0.25T sw . Moreover, compared with the conventional real-time-update PWM, the duty cycle is not limited and the grid-side current quality is similar. Finally, the simulation verifies the effectiveness of the proposed method.