Biomechanical evaluation of a microstructured zirconia implant by a removal torque comparison with a standard Ti-SLA implant.

作者: Kai-Hendrik Bormann , Nils-Claudius Gellrich , Heinz Kniha , Michel Dard , Marco Wieland

DOI: 10.1111/J.1600-0501.2011.02291.X

关键词: Implant typesTitaniumRemoval torqueDentistryTitanium surfaceBone tissueImplantCubic zirconiaDental Stress AnalysisMaterials science

摘要: … calculation of the tolerance levels for a non-inferiority test, to determine if the test implant, ie zirconia… -SLA, using a one tail comparison at P < 0.10. The P-values for all comparisons were …

参考文章(30)
Gerold Klaus, Ralf J Kohal, A zirconia implant-crown system: a case report. International Journal of Periodontics & Restorative Dentistry. ,vol. 24, pp. 147- 153 ,(2004)
Donald M Brunette, Pentti Tengvall, Marcus Textor, Peter Thomsen, Marcus Textor, Caroline Sittig, Vinzenz Frauchiger, Samuele Tosatti, Donald M Brunette, Properties and Biological Significance of Natural Oxide Films on Titanium and Its Alloys Springer, Berlin, Heidelberg. pp. 171- 230 ,(2001) , 10.1007/978-3-642-56486-4_7
Michael Gahlert, Stefan Röhling, Marco Wieland, Stefan Eichhorn, Helmut Küchenhoff, Heinz Kniha, A comparison study of the osseointegration of zirconia and titanium dental implants. A biomechanical evaluation in the maxilla of pigs. Clinical Implant Dentistry and Related Research. ,vol. 12, pp. 297- 305 ,(2010) , 10.1111/J.1708-8208.2009.00168.X
T ALBREKTSSON, H HANSSON, B IVARSSON, Interface analysis of titanium and zirconium bone implants. Biomaterials. ,vol. 6, pp. 97- 101 ,(1985) , 10.1016/0142-9612(85)90070-5
Tobias Jarmar, Anders Palmquist, Rickard Brånemark, Leif Hermansson, Håkån Engqvist, Peter Thomsen, Characterization of the surface properties of commercially available dental implants using scanning electron microscopy, focused ion beam, and high-resolution transmission electron microscopy. Clinical Implant Dentistry and Related Research. ,vol. 10, pp. 11- 22 ,(2008) , 10.1111/J.1708-8208.2007.00056.X
Yasumasa Akagawa, Yoichiro Ichikawa, Hiromasa Nikai, Hiromichi Tsuru, Interface histology of unloaded and early loaded partially stabilized zirconia endosseous implant in initial bone healing. Journal of Prosthetic Dentistry. ,vol. 69, pp. 599- 604 ,(1993) , 10.1016/0022-3913(93)90289-Z
Lars Sennerby, Amir Dasmah, Birgitta Larsson, Mattias Iverhed, Bone tissue responses to surface-modified zirconia implants: A histomorphometric and removal torque study in the rabbit. Clinical Implant Dentistry and Related Research. ,vol. 7, ,(2005) , 10.1111/J.1708-8208.2005.TB00070.X
Y. Josset, Z. Oum'Hamed, A. Zarrinpour, M. Lorenzato, J. J. Adnet, D. Laurent-Maquin, In vitro reactions of human osteoblasts in culture with zirconia and alumina ceramics. Journal of Biomedical Materials Research. ,vol. 47, pp. 481- 493 ,(1999) , 10.1002/(SICI)1097-4636(19991215)47:4<481::AID-JBM4>3.0.CO;2-Y
D. L. Cochran, P. V. Nummikoski, F. L. Higginbottom, J. S. Hermann, S. R. Makins, D. Buser, Evaluation of an endosseous titanium implant with a sandblasted and acid‐etched surface in the canine mandible: radiographic results Clinical Oral Implants Research. ,vol. 7, pp. 240- 252 ,(1996) , 10.1034/J.1600-0501.1996.070306.X
T. Minamizato, Slip-cast zirconia dental roots with tunnels drilled by laser process Journal of Prosthetic Dentistry. ,vol. 63, pp. 677- 684 ,(1990) , 10.1016/0022-3913(90)90326-8