Combined Homogeneous Region Localization and Automated Evaluation of Radiation Dose Dependent Contrast-to-Noise Ratio in Dual Energy Abdominal CT

作者: Minsoo Chun , Jong-Hyo Kim

DOI: 10.1007/978-3-319-13692-9_27

关键词: Body sizeAbdominal ctRadiation doseMaterials scienceTube (fluid conveyance)Dual energyHomogeneousRadiationContrast-to-noise ratioNuclear medicine

摘要: This study presents a homogeneous region localization technique combined with automated evaluation of radiation dose-dependent contrast-to-noise ratio in dual energy abdominal CT. Patient body size was calculated using growing segmentation and used to estimate size-specific dose estimate, are automatically evaluated by proposed technique. Contrast-to-noise turned out be similar between low high tube potential for both pre- post-contrast phases, while is remarkably lower at 80 kVp. Low can recommended reduce maintaining contrast-to-noise.

参考文章(8)
Hairil Rashmizal Abdul Razak, Wan Mazlina Md Saad, Said Mohd Shaffiq Said Rahmat, Effects of different tube potentials and iodine concentrations on image enhancement, contrast-to-noise ratio and noise in micro-CT images: a phantom study. Quantitative imaging in medicine and surgery. ,vol. 3, pp. 256- 261 ,(2013) , 10.3978/J.ISSN.2223-4292.2013.10.04
Jia Wang, Xinhui Duan, Jodie A. Christner, Shuai Leng, Lifeng Yu, Cynthia H. McCollough, Attenuation-based estimation of patient size for the purpose of size specific dose estimation in CT. Part I. Development and validation of methods using the CT image. Medical Physics. ,vol. 39, pp. 6764- 6771 ,(2012) , 10.1118/1.4754303
Zsolt Szucs-Farkas, Francis R. Verdun, Gabriel von Allmen, Roberto L. Mini, Peter Vock, Effect of X-ray Tube Parameters, Iodine Concentration, and Patient Size on Image Quality in Pulmonary Computed Tomography Angiography: A Chest-Phantom-Study Investigative Radiology. ,vol. 43, pp. 374- 381 ,(2008) , 10.1097/RLI.0B013E3181690042
Thomas G. Flohr, Cynthia H. McCollough, Herbert Bruder, Martin Petersilka, Klaus Gruber, Christoph Süβ, Michael Grasruck, Karl Stierstorfer, Bernhard Krauss, Rainer Raupach, Andrew N. Primak, Axel Küttner, Stefan Achenbach, Christoph Becker, Andreas Kopp, Bernd M. Ohnesorge, First performance evaluation of a dual-source CT (DSCT) system. European Radiology. ,vol. 16, pp. 256- 268 ,(2006) , 10.1007/S00330-005-2919-2
Guoquan Cao, Kun Tang, Ling Wang, Rui Li, Jie Lin, Xiangwu Zheng, Effect of Low Tube Voltage on Image Quality, Radiation Dose, and Low-Contrast Detectability at Abdominal Multidetector CT: Phantom Study BioMed Research International. ,vol. 2012, pp. 130169- 130169 ,(2012) , 10.1155/2012/130169
Ichiro Ikuta, Graham I. Warden, Katherine P. Andriole, Ramin Khorasani, Aaron Sodickson, Estimating Patient Dose from X-ray Tube Output Metrics: Automated Measurement of Patient Size from CT Images Enables Large-scale Size-specific Dose Estimates Radiology. ,vol. 270, pp. 472- 480 ,(2013) , 10.1148/RADIOL.13122727
David M. Hough, Joel G. Fletcher, Katharine L. Grant, Jeff L. Fidler, Lifeng Yu, Jennifer R. Geske, Rickey E. Carter, Rainer Raupach, Bernhard Schmidt, Thomas Flohr, Cynthia H. McCollough, Lowering Kilovoltage to Reduce Radiation Dose in Contrast-Enhanced Abdominal CT: Initial Assessment of a Prototype Automated Kilovoltage Selection Tool American Journal of Roentgenology. ,vol. 199, pp. 1070- 1077 ,(2012) , 10.2214/AJR.12.8637
John Boone, Keith Strauss, Dianna Cody, Cynthia McCollough, Michael McNitt-Gray, Thomas Toth, Marilyn Goske, Donald Frush, Size-Specific Dose Estimates (SSDE) in Pediatric and Adult Body CT Examinations AAPM. ,(2011) , 10.37206/143