作者: Adekunle O. Adelaja , Jaco Dirker , Josua P. Meyer
DOI: 10.1016/J.APENERGY.2014.01.072
关键词: Fourier number 、 Convective heat transfer 、 Heat transfer coefficient 、 Biot number 、 Heat transfer 、 Materials science 、 Thermodynamics 、 Thermal conduction 、 Mechanics 、 Nusselt number 、 Heat flux
摘要: Abstract Conjugate heat transfer in laminar tube flow with convective boundary conditions is considered analytically. The steady state problem involving two-dimensional wall and axial fluid conduction solved using separation of variables for a thick walled cylindrical pipe. effects the thickness, external Biot number wall-to-fluid thermal conductivity ratio are investigated on flux, bulk temperatures. Results presented cases when thickness between 0.1 2, ranging 10, 3 100. These parameters found to significantly affect characteristics at entrance region, instance, increase results reduced flux while result increased flux. Decrease both correspond decreased temperature profiles.