Methodologies and tools for proton beam design for lung tumors

作者: Michael F Moyers , Daniel W Miller , David A Bush , Jerry D Slater

DOI: 10.1016/S0360-3016(00)01555-8

关键词: Radiation treatment planningSeven Management and Planning ToolsBeam (structure)Normal tissueCt numberMedicineBody movementPlanning target volumeRadiation therapyNuclear medicineBiomedical engineering

摘要: … design as did Strategy 2. In addition, the planner had to calculate manually the target motions perpendicular to the beam … target volume for all beams and beam design steps. Drawing of …

参考文章(11)
David A. Bush, Jerry D. Slater, Reiner Bonnet, Gregory A. Cheek, Richard D. Dunbar, Michael Moyers, James M. Slater, Proton-Beam Radiotherapy for Early-Stage Lung Cancer Chest. ,vol. 116, pp. 1313- 1319 ,(1999) , 10.1378/CHEST.116.5.1313
Ernesto Fontenla, Charles A. Pelizzari, George T. Y. Chen, Implications of 3-dimensional target shape and motion in aperture design Medical Physics. ,vol. 23, pp. 1431- 1441 ,(1996) , 10.1118/1.597874
M Urie, M Goitein, M Wagner, Compensating for heterogeneities in proton radiation therapy Physics in Medicine and Biology. ,vol. 29, pp. 553- 566 ,(1984) , 10.1088/0031-9155/29/5/008
J.W. Wong, M.B. Sharpe, D.A. Jaffray, J.M. Robertson, J.S. Stromberg, V.R. Kini, A.A. Martinez, 60 The use of active breathing control (ABC) to minimize breathing motion during radiation therapy International Journal of Radiation Oncology Biology Physics. ,vol. 39, pp. 164- ,(1997) , 10.1016/S0360-3016(97)80617-7
André Wambersie, THE INTERNATIONAL COMMISSION ON RADIATION UNITS AND MEASUREMENTS Journal of the International Commission on Radiation Units and Measurements. ,vol. 5, pp. 3- 4 ,(2001) , 10.1093/JICRU/NDI017
Michael Goitein, Calculation of the uncertainty in the dose delivered during radiation therapy Medical Physics. ,vol. 12, pp. 608- 612 ,(1985) , 10.1118/1.595762
M.M. Urie, M. Goitein, K. Doppke, J.G. Kutcher, T. LoSasso, R. Mohan, J.E. Munzenrider, M. Sontag, J.W. Wong, The role of uncertainty analysis in treatment planning International Journal of Radiation Oncology Biology Physics. ,vol. 21, pp. 91- 107 ,(1991) , 10.1016/0360-3016(91)90170-9
Michael Goitein, Limitations of two-dimensional treatment planning programs Medical Physics. ,vol. 9, pp. 580- 586 ,(1982) , 10.1118/1.595226
D A Bush, R D Dunbar, R Bonnet, J D Slater, G A Cheek, J M Slater, Pulmonary injury from proton and conventional radiotherapy as revealed by CT. American Journal of Roentgenology. ,vol. 172, pp. 735- 739 ,(1999) , 10.2214/AJR.172.3.10063871
Michael Goitein, Compensation for inhomogeneities in charged particle radiotherapy using computed tomography. International Journal of Radiation Oncology Biology Physics. ,vol. 4, pp. 499- 508 ,(1978) , 10.1016/0360-3016(78)90087-1