Performance of DFIG Wind Turbine Using Dynamic Voltage Restorer Based Fuzzy Logic Controller

作者: Kaoutar Rabyi , Hassane Mahmoudi

DOI: 10.1007/978-3-030-12065-8_14

关键词:

摘要: In this paper a Doubly Fed Induction Generator (DFIG) based Dynamic Voltage Restorer (DVR) is proposed to handle voltage sag and swell when the DFIG connected electrical grid, DVR which constitution of three H-bridge inverters supplied through common DC capacitor, can recover 50%, alternatively it operates as an uninterruptable power supply failure occurs in grid supply. The Fuzzy Logic Controller (FLC) be used instead proportional controllers PI because its efficiency nonlinear systems; there are two side converter replaced by FLC, simulations were carried out simulink/Matlab software, results show reliability FLC terms synchronization time.

参考文章(11)
Abobkr Hamida Abobkr, M. E. El-Hawary, Fault ride-through capability of doubly-fed induction generators based wind turbines electrical power and energy conference. pp. 8- 15 ,(2015) , 10.1109/EPEC.2015.7379919
Alejandro Rolán, Joaquín Pedra, Felipe Córcoles, Detailed study of DFIG-based wind turbines to overcome the most severe grid faults International Journal of Electrical Power & Energy Systems. ,vol. 62, pp. 868- 878 ,(2014) , 10.1016/J.IJEPES.2014.05.031
A. Gaillard, P. Poure, S. Saadate, M. Machmoum, Variable speed DFIG wind energy system for power generation and harmonic current mitigation Renewable Energy. ,vol. 34, pp. 1545- 1553 ,(2009) , 10.1016/J.RENENE.2008.11.002
Andres E. Leon, Marcelo F. Farias, Pedro E. Battaiotto, Jorge A. Solsona, María Inés Valla, Control Strategy of a DVR to Improve Stability in Wind Farms Using Squirrel-Cage Induction Generators IEEE Transactions on Power Systems. ,vol. 26, pp. 1609- 1617 ,(2011) , 10.1109/TPWRS.2010.2088141
Mario Gonzalez, Victor Cardenas, Luis Moran, Josh Espinoza, Selecting between linear and nonlinear control in a dynamic voltage restorer power electronics specialists conference. pp. 3867- 3872 ,(2008) , 10.1109/PESC.2008.4592559
Hao Ying, Yongsheng Ding, Shaokuan Li, Shihuang Shao, Comparison of necessary conditions for typical Takagi-Sugeno and Mamdani fuzzy systems as universal approximators systems man and cybernetics. ,vol. 29, pp. 508- 514 ,(1999) , 10.1109/3468.784177
Mohammad Farhadi-Kangarlu, Ebrahim Babaei, Frede Blaabjerg, A comprehensive review of dynamic voltage restorers International Journal of Electrical Power & Energy Systems. ,vol. 92, pp. 136- 155 ,(2017) , 10.1016/J.IJEPES.2017.04.013
Abdul R. Ofoli, Fuzzy-Logic Applications in Electric Drives and Power Electronics Power Electronics Handbook (Fourth Edition). pp. 1221- 1243 ,(2018) , 10.1016/B978-0-12-811407-0.00040-4
Xi Wu, Yajing Guan, Wei Ning, Reactive power control strategy of DFIG‐based wind farm to mitigate SSO The Journal of Engineering. ,vol. 2017, pp. 1290- 1294 ,(2017) , 10.1049/JOE.2017.0537