Intra- and Intersession Repeatability of a Double-Pass Instrument

作者: Meritxell Vilaseca , Elvira Peris , Jaume Pujol , Rosa Borras , Montserrat Arjona

DOI: 10.1097/OPX.0B013E3181EA1AD3

关键词:

摘要: ABSTRACTPurpose.To evaluate the intra- and intersession repeatability of optical quality parameters provided by Optical Quality Analysis System (OQAS), which is based on double-pass technique.Methods.We performed measurements using OQAS 20 eyes 10 healthy subjec

参考文章(25)
Meritxell Vilaseca, Montserrat Arjona, Jaume Pujol, Luis Issolio, José L. Güell, Optical quality of foldable monofocal intraocular lenses before and after injection: Comparative evaluation using a double-pass system Journal of Cataract and Refractive Surgery. ,vol. 35, pp. 1415- 1423 ,(2009) , 10.1016/J.JCRS.2009.03.022
GS Rubin, RF Galbraith, M Sims, LE Culham, Crossland, A new quantitative technique to determine the number and extent of preferred retinal loci in macular disease Investigative Ophthalmology & Visual Science. ,vol. 43, pp. 3822- 3822 ,(2002)
BS Hawkins, MJ Marsh, L Dong, Consistency Between Visual Acuity Scores Obtained at Different Test Distances: Theory versus Observations in Multiple Studies Investigative Ophthalmology & Visual Science. ,vol. 43, pp. 3823- 3823 ,(2002)
Raul Martin, Victoria de Juan, Guadalupe Rodriguez, Soraya Fonseca, Sofia Martin, Contact lens-induced corneal peripheral swelling: Orbscan repeatability. Optometry and Vision Science. ,vol. 86, pp. 340- 349 ,(2009) , 10.1097/OPX.0B013E318199D095
Robert Monte´s-Mico´, Jorge L. Alio´, W. Neil Charman, Postblink changes in the ocular modulation transfer function measured by a double-pass method. Investigative Ophthalmology & Visual Science. ,vol. 46, pp. 4468- 4473 ,(2005) , 10.1167/IOVS.05-0609
Willem J. Hament, Vaisjaly A. Nabar, Rudy M.M.A. Nuijts, Repeatability and validity of Zywave aberrometer measurements Journal of Cataract and Refractive Surgery. ,vol. 28, pp. 2135- 2141 ,(2002) , 10.1016/S0886-3350(02)01333-0
Meritxell Vilaseca, Adenay Padilla, Jaume Pujol, Juan C Ondategui, Pablo Artal, Jose L Güell, None, Optical Quality One Month After Verisyse and Veriflex Phakic IOL Implantation and Zeiss MEL 80 LASIK for Myopia From 5.00 to 16.50 Diopters Journal of Refractive Surgery. ,vol. 25, pp. 689- 698 ,(2009) , 10.3928/1081597X-20090707-03
Alain Saad, Marc Saab, Damien Gatinel, Repeatability of measurements with a double-pass system Journal of Cataract and Refractive Surgery. ,vol. 36, pp. 28- 33 ,(2010) , 10.1016/J.JCRS.2009.07.033
Dolores Ortiz, Jorge L. Alió, Jose Ruiz-Colechá, Ulrike Oser, Grading nuclear cataract opacity by densitometry and objective optical analysis. Journal of Cataract and Refractive Surgery. ,vol. 34, pp. 1345- 1352 ,(2008) , 10.1016/J.JCRS.2008.04.022
Xu Cheng, Nikole L. Himebaugh, Pete S. Kollbaum, Larry N. Thibos, Arthur Bradley, Test-retest reliability of clinical Shack-Hartmann measurements. Investigative Ophthalmology & Visual Science. ,vol. 45, pp. 351- 360 ,(2004) , 10.1167/IOVS.03-0265