High-performance Composites for Applications in Medical Engineering: Susceptibility Artifacts in Magnetic Resonance Imaging

作者: A. Endruweit , S. Fritzsche , R. Thull , A. Haase , W. Baur

DOI: 10.1177/0731684405042954

关键词:

摘要: The interaction of carbon fiber/epoxy composite parts with the magnetic fields in resonance imaging (MRI) for medical diagnostics has been quantitatively estimated example Riechert stereotactic head ring. Rings from carbon/epoxy have compared rings other materials respect to their influence on applied field. For a fiber volume fraction ’ 0.5 and an angle between orientation field direction 90, disturbances caused by are similar those non-ferromagnetic metals as Cu or Al. Due significantly lower susceptibility values, HT fibers be preferred HM fields. Induction significant macroscopic eddy currents changes flux through is not expected.

参考文章(20)
L. Zamorano, B. Bauer-Kirpes, M. Dujovny, G. Malik, J. Ausman, Application of multimodality imaging stereotactic localization in the surgical management of vascular lesions. Acta Neurochirurgica. ,vol. 52, pp. 67- 68 ,(1991) , 10.1007/978-3-7091-9160-6_19
Lucia Zamorano, Manuel Dujovny, Cristina Chavantes, Ghaus Malik, James Ausman, Image-guided stereotactic centered craniotomy and laser resection of solid intracranial lesions. Stereotactic and Functional Neurosurgery. ,vol. 54, pp. 398- 403 ,(1990) , 10.1159/000100242
Stefan Posse, Walter P. Aue, Susceptibility artifacts in spin-echo and gradient-echo imaging Journal of Magnetic Resonance. ,vol. 88, pp. 473- 492 ,(1990) , 10.1016/0022-2364(90)90282-E
E. M. Purcell, H. C. Torrey, R. V. Pound, Resonance Absorption by Nuclear Magnetic Moments in a Solid Physical Review. ,vol. 69, pp. 37- 38 ,(1946) , 10.1103/PHYSREV.69.37
Sigurds Arajs, C. A. Moyer, G. Kote, I. L. Kalnins, Diamagnetic susceptibility of carbon fibre reinforced epoxy resin composites Journal of Materials Science. ,vol. 13, pp. 2061- 2063 ,(1978) , 10.1007/BF00552920
C. B. Scott, D. B. Fischbach, Diamagnetic studies on as‐processed carbon fibers Journal of Applied Physics. ,vol. 47, pp. 5329- 5335 ,(1976) , 10.1063/1.322556
C.J.G. Bakker, R. Bhagwandien, M.A. Moerland, M. Fuderer, Susceptibility artifacts in 2DFT spin-echo and gradient-echo imaging: The cylinder model revisited Magnetic Resonance Imaging. ,vol. 11, pp. 539- 548 ,(1993) , 10.1016/0730-725X(93)90473-Q
L. Dade Lunsford, A. Julio Martinez, Richard E. Latchaw, Stereotaxic surgery with a magnetic resonance- and computerized tomography-compatible system. Journal of Neurosurgery. ,vol. 64, pp. 872- 878 ,(1986) , 10.3171/JNS.1986.64.6.0872
ZH Cho, YongMan Ro, Reduction of susceptibility artifact in gradient-echo imaging. Magnetic Resonance in Medicine. ,vol. 23, pp. 193- 200 ,(1992) , 10.1002/MRM.1910230120
A Ericsson, A Hemmingsson, B Jung, G O Sperber, Calculation of MRI artifacts caused by static field disturbances Physics in Medicine and Biology. ,vol. 33, pp. 1103- 1112 ,(1988) , 10.1088/0031-9155/33/10/001