Medicine preparation errors in ten Spanish neonatal intensive care units.

作者: Ainara Campino , Casilda Arranz , Maria Unceta , Miguel Rueda , Beatriz Sordo

DOI: 10.1007/S00431-015-2615-4

关键词:

摘要: This study assessed the rate of errors in intravenous medicine preparation at bedside neonatal intensive care units vs error a hospital pharmacy service. We conducted prospective observational between June and September 2013. Ten Spanish one service participated study. Two types were considered: calculation accuracy errors. A total 522 samples collected: 238 vancomycin, 139 gentamicin, 39 phenobarbital 88 caffeine citrate preparations. Of these, 444 collected by nurses units, 60 provided Overall, 18 excluded from analysis. detected 6/444 (1.35 %) 243/444 (54.7 units. In contrast, service, no detected, but there 23/60 (38.3 samples.

参考文章(30)
Chittiwat Suprasongsin, Aruchalean Watanachai, Deadspace: a potential error in concentration of medication during dilutional process in neonates. Journal of the Medical Association of Thailand Chotmaihet thangphaet. ,vol. 86, pp. 1128- 1132 ,(2003)
Catherine M. Crill, Stephanie J. Phelps, Emily B. Hak, Pediatric Injectable Drugs (The Teddy Bear Book) ,(2010)
Dennis D. Cote, Mark G. Torchia, Robotic system for i.v. antineoplastic drug preparation: description and preliminary evaluation under simulated conditions American Journal of Health-system Pharmacy. ,vol. 46, pp. 2286- 2293 ,(1989) , 10.1093/AJHP/46.11.2286
Daniel W Wheeler, Dionysios D Remoundos, Kim D Whittlestone, Timothy P House, David K Menon, Calculation of doses of drugs in solution: are medical students confused by different means of expressing drug concentrations? Drug Safety. ,vol. 27, pp. 729- 734 ,(2004) , 10.2165/00002018-200427100-00003
A. Campino, E. Santesteban, M. Garcia, M. Rueda, A. Valls-i-Soler, Errores en la preparación de fármacos intravenosos en una Unidad de Cuidados Intensivos Neonatal. Una potencial fuente de eventos adversos Anales De Pediatria. ,vol. 79, pp. 21- 25 ,(2013) , 10.1016/J.ANPEDI.2012.09.005
M. Popescu, R. Vialet, A. Loundou, F. Peyron, M. Buès-Charbit, Étude de la variabilité dans les reconstitutions de vancomycine intraveineuse en réanimation pédiatrique Annales Francaises D Anesthesie Et De Reanimation. ,vol. 30, pp. 726- 729 ,(2011) , 10.1016/J.ANNFAR.2011.04.013
S. Avenel, A. Bomkratz, G. Dassieu, J.C. Janaud, C. Danan, Incidence des prescriptions hors autorisation de mise sur le marché en réanimation néonatale Archives De Pediatrie. ,vol. 7, pp. 143- 147 ,(2000) , 10.1016/S0929-693X(00)88083-5
Arthur D. Hirschfelder, THE UNITED STATES PHARMACOPEIAL CONVENTION JAMA. ,vol. 95, pp. 220- 220 ,(1930) , 10.1001/JAMA.1930.02720030050030
K Allegaert, BJ Anderson, M Vrancken, A Debeer, K Desmet, K Cosaert, D Tibboel, H Devlieger, Impact of a paediatric vial on the magnitude of systematic medication errors in neonates Paediatric and Perinatal Drug Therapy. ,vol. 7, pp. 59- 63 ,(2006) , 10.1185/146300906X105096