High-performance liquid chromatography of eburnane alkaloids

作者: M. Gazdag , G. Szepesi , K. Csomor

DOI: 10.1016/S0021-9673(00)82423-1

关键词:

摘要: Abstract Methods developed for the separation of eburnane alkaloids have been applied solving different analytical problems; plant extracts, mother liquors and pharmaceutical formulations analysed on both reversed-phase silica packings. For determination apovincaminic acid ethyl ester (vinpocetine) in human blood plasma octylsilica was used as stationary phase acetonitrile–0.01 M aqueous ammonium carbonate eluent. quantitation apovincamine can be an internal standard. The detection limit found to 2 ng/ml. To determine corresponding acids derivatives a ion-pair chromatographic method developed.

参考文章(3)
G. Szepesi, M. Gazdag, R. Iváncsics, Normal-phase dynamic (solvent-generated) molecular complexation chromatography using anionic ion exchangers Journal of Chromatography A. ,vol. 244, pp. 33- 48 ,(1982) , 10.1016/S0021-9673(00)80120-X
G. Szepesi, M. Gazdag, High-performance liquid chromatography of eburnane alkaloids Journal of Chromatography A. ,vol. 204, pp. 341- 348 ,(1981) , 10.1016/S0021-9673(00)81677-5
G. Szepesi, M. Gazdag, High-performance liquid chromatography of eburnane alkaloids : II. Separations on silica Journal of Chromatography A. ,vol. 205, pp. 57- 64 ,(1981) , 10.1016/S0021-9673(00)81813-0