A pixel detector for the protein crystallography beamline at the SLS

作者: Ch Brönnimann , R Baur , E.F Eikenberry , P Fischer , S Florin

DOI: 10.1016/S0168-9002(01)01916-7

关键词:

摘要: At the Paul Scherrer Institute a new synchrotron light source is currently under construction, Swiss Light Source (SLS), which will be operational in summer 2001. Among first beamlines high brightness, micro-focusing protein crystallography beamline. It equipped with pixel detector, has several features of interest for next generation detectors. The point spread function and effect charge sharing was measured prototype detector test experiment at European Synchrotron Radiation Facility Grenoble. concepts SLS presented as well results from radiation hard chips.

参考文章(6)
P. Fischer, An area efficient 128 channel counter chip Nuclear Instruments & Methods in Physics Research Section A-accelerators Spectrometers Detectors and Associated Equipment. ,vol. 378, pp. 297- 300 ,(1996) , 10.1016/0168-9002(96)00200-8
E. Beuville, J.-F. Beche, C. Cork, V. Douence, T. Earnest, J. Millaud, D. Nygren, H. Padmore, B. Turko, G. Zizka, P. Datte, N.-H. Xuong, A 16 × 16 pixel array detector for protein crystallography Nuclear Instruments & Methods in Physics Research Section A-accelerators Spectrometers Detectors and Associated Equipment. ,vol. 395, pp. 429- 434 ,(1997) , 10.1016/S0168-9002(96)01234-X
P. Fischer, J. Hausmann, M. Overdick, B. Raith, N. Wermes, L. Blanquart, V. Bonzom, P. Delpierre, A counting pixel readout chip for imaging applications Nuclear Instruments & Methods in Physics Research Section A-accelerators Spectrometers Detectors and Associated Equipment. ,vol. 405, pp. 53- 59 ,(1998) , 10.1016/S0168-9002(97)01146-7
M. Campbell, E.H.M. Heijne, G. Meddeler, E. Pernigotti, W. Snoeys, A Readout Chip for a 64 x 64 Pixel Matrix with 15-bit Single Photon Counting* ieee nuclear science symposium. ,vol. 45, pp. 751- 753 ,(1997) , 10.1109/23.682629
P. Fischer, J. Hausmann, A. Helmich, M. Lindner, N. Wermes, L. Blanquart, A counting pixel chip and sensor system for X-ray imaging IEEE Transactions on Nuclear Science. ,vol. 46, pp. 1070- 1074 ,(1999) , 10.1109/23.790828
M. Dentan, P. Abbon, E. Delagnes, N. Fourches, D. Lachartre, F. Lugiez, B. Paul, M. Rouger, R. Truche, J.P. Blanc, C. Leroux, E. Delevoye-Orsier, J.L. Pelloie, J. de Pontcharra, O. Flament, J.M. Guebhard, J.L. Leray, J. Montaron, O. Musseau, A. Vitez, L. Blanquart, J.J. Aubert, V. Bonzom, P. Delpierre, M.C. Habrard, A. Mekkaoui, R. Potheau, J. Ardelean, A. Hrisoho, D. Breton, DMILL, a mixed analog-digital radiation-hard BICMOS technology for high energy physics electronics nuclear science symposium and medical imaging conference. ,vol. 43, pp. 1763- 1767 ,(1995) , 10.1109/23.507218