Matrix‐assisted laser desorption of peptides and proteins using a quadrupole ion trap mass spectrometer

作者: Jae C. Schwartz , Mark E. Bier

DOI: 10.1002/RCM.1290070107

关键词:

摘要: The analytical capabilities of the combination matrix-assisted laser desorption with a quadrupole ion trap utilizing injection are demonstrated using peptides and proteins molecular weights up to 43 kDa.

参考文章(21)
John N. Louris, Jennifer S. Brodbelt-Lustig, R. Graham Cooks, Gary L. Glish, Gary J. van Berkel, Scott A. McLuckey, Ion isolation and sequential stages of mass spectrometry in a quadrupole ion trap mass spectrometer International Journal of Mass Spectrometry and Ion Processes. ,vol. 96, pp. 117- 137 ,(1990) , 10.1016/0168-1176(90)87025-C
Ronald C. Beavis, Brian T. Chait, Velocity distributions of intact high mass polypeptide molecule ions produced by matrix assisted laser desorption Chemical Physics Letters. ,vol. 181, pp. 479- 484 ,(1991) , 10.1016/0009-2614(91)90384-L
R. L. Hettich, M. V. Buchanan, Investigation of UV matrix-assisted laser desorption fourier transform mass spectrometry for peptides Journal of the American Society for Mass Spectrometry. ,vol. 2, pp. 22- 28 ,(1991) , 10.1016/1044-0305(91)80057-E
David N. Heller, Ihor. Lys, Robert J. Cotter, O. Manuel. Uy, Laser desorption from a probe in the cavity of a quadrupole ion storage mass spectrometer Analytical Chemistry. ,vol. 61, pp. 1083- 1086 ,(1989) , 10.1021/AC00185A008
Michael. Karas, Franz. Hillenkamp, Laser desorption ionization of proteins with molecular masses exceeding 10,000 daltons Analytical Chemistry. ,vol. 60, pp. 2299- 2301 ,(1988) , 10.1021/AC00171A028
Jae C. Schwartz, Ian Jaardine, High resolution parent-ion selection/isolation using a quadrupole ion-trap mass spectrometer Rapid Communications in Mass Spectrometry. ,vol. 6, pp. 313- 317 ,(1992) , 10.1002/RCM.1290060419
John A. Castro, Claus Köster, Charles Wilkins, R. J. Cotter, Matrix-assisted laser desorption/ionization of high-mass molecules by Fourier-transform mass spectrometry Rapid Communications in Mass Spectrometry. ,vol. 6, pp. 239- 241 ,(1992) , 10.1002/RCM.1290060403
K. A. Cox, J. D. Williams, R. G. Cooks, R. E. Kaiser, Quadrupole ion trap mass spectrometry: Current applications and future directions for peptide analysis Journal of Mass Spectrometry. ,vol. 21, pp. 226- 241 ,(1992) , 10.1002/BMS.1200210503
Raymond E. Kaiser, R. Graham Cooks, George C. Stafford, John E.P. Syka, Philip H. Hemberger, Operation of a quadrupole ion trap mass spectrometer to achieve high mass/charge ratios International Journal of Mass Spectrometry and Ion Processes. ,vol. 106, pp. 79- 115 ,(1991) , 10.1016/0168-1176(91)85013-C
Jae C. Schwartz, John E. P. Syka, Ian Jardine, High resolution on a quadrupole ion trap mass spectrometer Journal of the American Society for Mass Spectrometry. ,vol. 2, pp. 198- 204 ,(1991) , 10.1016/1044-0305(91)80044-8