Determination of the Hapten Density of Immuno-Conjugates by Matrix-Assisted UV Laser Desorption/Ionization Mass Spectrometry

作者: I. Wengatz , R. D. Schmid , S. Kreißig , C. Wittmann , B. Hock

DOI: 10.1080/00032719208020070

关键词:

摘要: Abstract Information on the hapten densities of immunoconjugates, that is number coupled haptens, important for production antibodies directed towards respective hapten, e.g. a pesticide. Matrix-assisted UV laser desorption mass spectrometry (MALDI) provides sensitive method measurement molecular weight large bioorganic compounds. The resolution approx. 100, currently achievable with this technique in conjunction careful centroiding procedure peaks, sufficient determination density. Different immunoconjugates and labeled enzymes used enzyme immunoassays were investigated order to evaluate density, as inferred from measured differences between conjugated nonconjugated carrier molecule. pesticides methabenzthiazuron, phenoxybenzoic acid derivatives atrazine pyrethroids haptens. Hapten determined spectra compared those based UV...

参考文章(10)
Bernard F. Erlanger, Felix Borek, Sam M. Beiser, Seymour Lieberman, Steroid-protein conjugates. II. Preparation and characterization of conjugates of bovine serum albumin with progesterone, deoxycorticosterone, and estrone. Journal of Biological Chemistry. ,vol. 234, pp. 1090- 1094 ,(1959) , 10.1016/S0021-9258(18)98136-6
Bernard F. Erlanger, Felix Borek, Sam M. Beiser, Seymour Lieberman, Steroid-protein conjugates. I. Preparation and characterization of conjugates of bovine serum albumin with testosterone and with cortisone. Journal of Biological Chemistry. ,vol. 228, pp. 713- 727 ,(1957) , 10.1016/S0021-9258(18)70654-6
Michael. Karas, Franz. Hillenkamp, Laser desorption ionization of proteins with molecular masses exceeding 10,000 daltons Analytical Chemistry. ,vol. 60, pp. 2299- 2301 ,(1988) , 10.1021/AC00171A028
Michael Karas, Ute Bahr, Arndt Ingendoh, Franz Hillenkamp, Laserdesorptions‐Massenspektrometrie von Proteinen mit Molmassen zwischen 100000 und 250000 Dalton Angewandte Chemie. ,vol. 101, pp. 805- 806 ,(1989) , 10.1002/ANGE.19891010639
A. Overberg, M. Karas, U. Bahr, R. Kaufmann, F. Hillenkamp, Matrix‐assisted infrared‐laser (2.94 μm) desorption/ionization mass spectrometry of large biomolecules Rapid Communications in Mass Spectrometry. ,vol. 4, pp. 293- 296 ,(1990) , 10.1002/RCM.1290040808
P. Feigl, B. Schueler, F. Hillenkamp, LAMMA 1000, a new instrument for bulk microprobe mass analysis by pulsed laser irradiation International Journal of Mass Spectrometry and Ion Physics. ,vol. 47, pp. 15- 18 ,(1983) , 10.1016/0020-7381(83)87125-3
Richard A. J. O'Hair, John H. Bowie, Do the benzyl and silabenzyl anions show similar ion chemistry in the gas phase Rapid Communications in Mass Spectrometry. ,vol. 3, pp. 293- 294 ,(1989) , 10.1002/RCM.1290030905
PAUL K. NAKANE, AKIRA KAWAOI, Peroxidase-labeled antibody. A new method of conjugation Journal of Histochemistry and Cytochemistry. ,vol. 22, pp. 1084- 1091 ,(1974) , 10.1177/22.12.1084
Christine Wittmann, Bertold Hock, Improved enzyme immunoassay for the analysis of s‐triazines in water samples Food and Agricultural Immunology. ,vol. 1, pp. 211- 224 ,(1989) , 10.1080/09540108909354693