Chip-based amperometric enzyme sensor system for monitoring of bioprocesses by flow-injection analysis.

作者: M. Bäcker , D. Rakowski , A. Poghossian , M. Biselli , P. Wagner

DOI: 10.1016/J.JBIOTEC.2012.03.014

关键词:

摘要: A microfluidic chip integrating amperometric enzyme sensors for the detection of glucose, glutamate and glutamine in cell-culture fermentation processes has been developed. The enzymes glucose oxidase, oxidase glutaminase were immobilized by means cross-linking with glutaraldehyde on platinum thin-film electrodes integrated within a channel. biosensor was coupled to flow-injection analysis system electrochemical characterization sensors. have characterized terms sensitivity, linear working range limit. sensitivity evaluated from respective peak areas 1.47, 3.68 0.28 μAs/mM sensor, respectively. calibration curves up concentration 20 mM 10 glutamate. lower limit amounted be 0.05 respectively, 0.1 sensor. Experiments medium demonstrated good correlation between glutamate, concentrations measured chip-based biosensors differential-mode commercially available instrumentation. obtained results demonstrate feasibility realized monitoring bioprocesses.

参考文章(17)
Thomas Becker, Bernd Hitzmann, K. Muffler, Ralf Pörtner, Kenneth F. Reardon, Frank Stahl, Roland Ulber, Future aspects of bioprocess monitoring. Advances in Biochemical Engineering \/ Biotechnology. ,vol. 105, pp. 249- 293 ,(2006) , 10.1007/10_2006_036
Hung Lam, Yordan Kostov, Optical Instrumentation for Bioprocess Monitoring Advances in Biochemical Engineering \/ Biotechnology. ,vol. 116, pp. 125- 142 ,(2009) , 10.1007/10_2008_50
M. Bäcker, S. Pouyeshman, Th. Schnitzler, A. Poghossian, P. Wagner, M. Biselli, M. J. Schöning, A silicon‐based multi‐sensor chip for monitoring of fermentation processes Physica Status Solidi (a). ,vol. 208, pp. 1364- 1369 ,(2011) , 10.1002/PSSA.201001139
M. Bäcker, S. Beging, M. Biselli, A. Poghossian, J. Wang, W. Zang, P. Wagner, M.J. Schöning, Concept for a solid-state multi-parameter sensor system for cell-culture monitoring Electrochimica Acta. ,vol. 54, pp. 6107- 6112 ,(2009) , 10.1016/J.ELECTACTA.2009.02.091
Arshak Poghossian, Michael J. Schöning, Detecting Both Physical and (Bio‐)Chemical Parameters by Means of ISFET Devices Electroanalysis. ,vol. 16, pp. 1863- 1872 ,(2004) , 10.1002/ELAN.200403074
Mehriban Akin, Andreas Prediger, Merve Yuksel, Tim Höpfner, Dilek Odaci Demirkol, Sascha Beutel, Suna Timur, Thomas Scheper, A new set up for multi-analyte sensing: At-line bio-process monitoring Biosensors and Bioelectronics. ,vol. 26, pp. 4532- 4537 ,(2011) , 10.1016/J.BIOS.2011.05.018
M. Bäcker, L. Delle, A. Poghossian, M. Biselli, W. Zang, P. Wagner, M.J. Schöning, Electrochemical sensor array for bioprocess monitoring Electrochimica Acta. ,vol. 56, pp. 9673- 9678 ,(2011) , 10.1016/J.ELECTACTA.2011.04.030
Georg Locher, Bernhard Sonnleitner, Armin Fiechter, On-line measurement in biotechnology: techniques. Journal of Biotechnology. ,vol. 25, pp. 23- 53 ,(1992) , 10.1016/0168-1656(92)90108-L
Tim Höpfner, Arne Bluma, Guido Rudolph, Patrick Lindner, Thomas Scheper, A review of non-invasive optical-based image analysis systems for continuous bioprocess monitoring Bioprocess and Biosystems Engineering. ,vol. 33, pp. 247- 256 ,(2010) , 10.1007/S00449-009-0319-8
K Schügerl, L Brandes, T Dullau, K Holzhauer-Rieger, S Hotop, U Hübner, X Wu, W Zhou, Fermentation monitoring and control by on-line flow injection and liquid chromatography Analytica Chimica Acta. ,vol. 249, pp. 87- 100 ,(1991) , 10.1016/0003-2670(91)87012-V