Indoor exposure from building materials: A field study

作者: Dafni A. Missia , E. Demetriou , N. Michael , E.I. Tolis , J.G. Bartzis

DOI: 10.1016/J.ATMOSENV.2010.07.049

关键词:

摘要: Abstract The present study has been conducted in the frame of BUMA (Prioritization Building Materials Emissions as indoor pollution sources), a European funded project, aiming at assessing exposure to emitted compounds air. Field campaigns five (5) cities (Milan, Copenhagen, Dublin, Athens and Nicosia) were carried out. These covered weekly winter summer concentration measurements two (2) public buildings private houses each city. BTEX, terpenes, carbonyls measured using passive sampling sites inside building one outside. VOC emission on selected material have also performed Laboratory Emission Cell (FLEC). results concentrations for such formaldehyde (1.2–62.6 μg m−3), acetaldehyde (0.7–41.6 μg m−3), toluene (0.9–163.5 μg m−3), xylenes (0.2–177.5 μg m−3) acetone (2.8–308.8 μg m−3) shown diversity relatively significant sources depending type, age etc. Indoor these substances are varied type. percentage approximately 40% air quality levels originated from materials.

参考文章(42)
R. Shmulsky, C. Lungu, Patrick H Huelman, J. Y. Park, A. Bartekova, Laboratory evaluation of volatile organic compounds emissions from coated and uncoated oriented Strandboard Forest Products Journal. ,vol. 56, pp. 85- 90 ,(2006)
D. Marchl, P. Braun, U. Hott, P. Plieninger, H. Schleibinger, H. Rüden, VOC-Konzentrationen in Innenräumen des Grossraums Berlin im Zeitraum von 1988 bis 1999 Gefahrstoffe Reinhaltung Der Luft. ,vol. 61, pp. 26- 38 ,(2001)
Josefa Barrero-Moreno, D Sarigiannis, Otmar Geiss, Salvatore Tirendi, Erminio Marafante, Barbara Casati, Alberto Gotti, Vittorio Reina, Graziella Cimino-Reale, Dimitrois Kotzias, Exposure to multiple air contaminants in public buildings, schools and kindergartens-the European indoor air monitoring and exposure assessment (airmex) study Fresenius Environmental Bulletin. ,vol. 18, pp. 670- 681 ,(2009)
Hai Guo, Frank Murray, Steve Wilkinson, None, Evaluation of total volatile organic compound emissions from adhesives based on chamber tests Journal of The Air & Waste Management Association. ,vol. 50, pp. 199- 206 ,(2000) , 10.1080/10473289.2000.10464006
Hai Guo, Frank Murray, None, Determination of total volatile organic compound emissions from furniture polishes Clean Products and Processes. ,vol. 3, pp. 42- 48 ,(2001) , 10.1007/S100980100099
Elke Ilgen, Karsten Levsen, Jürgen Angerer, Peter Schneider, Joachim Heinrich, H.-Erich Wichmann, Aromatic hydrocarbons in the atmospheric environment – Part II: univariate and multivariate analysis and case studies of indoor concentrations Atmospheric Environment. ,vol. 35, pp. 1253- 1264 ,(2001) , 10.1016/S1352-2310(00)00490-8
H JARNSTROM, K SAARELA, P KALLIOKOSKI, A PASANEN, Reference values for structure emissions measured on site in new residential buildings in Finland Atmospheric Environment. ,vol. 41, pp. 2290- 2302 ,(2007) , 10.1016/J.ATMOSENV.2006.11.033
B. Clarisse, A.M. Laurent, N. Seta, Y. Le Moullec, A. El Hasnaoui, I. Momas, Indoor aldehydes: measurement of contamination levels and identification of their determinants in Paris dwellings Environmental Research. ,vol. 92, pp. 245- 253 ,(2003) , 10.1016/S0013-9351(03)00039-2