Ambulatory Blood Pressure Monitoring and Organ Damage

作者: Giuseppe Mancia , Gianfranco Parati

DOI: 10.1161/01.HYP.36.5.894

关键词:

摘要: Several papers have suggested that 24-hour average blood pressure (BP) is superior to office BP in relation hypertension target organ damage. This review article will specifically address the evidence provided this regard by either cross-sectional or longitudinal studies. It also critically discuss available data supporting concept not only values, but specific patterns occurring within 24 hours may clinical relevance. case for daytime versus nighttime BP, day/night difference, morning rise, and overall variability.

参考文章(53)
P Verdecchia, C Borgioni, A Ciucci, R Gattobigio, G Schillaci, N Sacchi, A Santucci, C Santucci, G Reboldi, C Porcellati, Prognostic significance of blood pressure variability in essential hypertension. Blood Pressure Monitoring. ,vol. 1, pp. 3- 11 ,(1996) , 10.1016/0895-7061(96)81482-8
Susumu Sasaki, Yusuke Yoneda, Hiroshi Fujita, Atsushi Uchida, Ken Takenaka, Toshiyuki Takesako, Hiroshi Itoh, Tetsuo Nakata, Kazuo Takeda, Masao Nakagawa, Association of blood pressure variability with induction of atherosclerosis in cholesterol-fed rats. American Journal of Hypertension. ,vol. 7, pp. 453- 459 ,(1994) , 10.1093/AJH/7.5.453
Giuseppe Mancia, Stefano Omboni, Antonella Ravogli, Gianfranco Parati, Alberto Zanchetti, Ambulatory blood pressure monitoring in the evaluation of antihypertensive treatment: additional information from a large data base Blood Pressure. ,vol. 4, pp. 148- 156 ,(1995) , 10.3109/08037059509077587
Jan A. Staessen, Leszek Bieniaszewski, Eoin O'Brien, Philippe Gosse, Hiroshi Hayashi, Yutaka Imai, Terukazu Kawasaki, Kuniaki Otsuka, Paolo Palatini, Lutgarde Thijs, Robert Fagard, Nocturnal Blood Pressure Fall on Ambulatory Monitoring in a Large International Database Hypertension. ,vol. 29, pp. 30- 39 ,(1997) , 10.1161/01.HYP.29.1.30
Giuseppe Mancia, Luisa Ulian, Gianfranco Parati, Silvia Trazzi, Increase in blood pressure reproducibility by repeated semi-automatic blood pressure measurements in the clinic environment. Journal of Hypertension. ,vol. 12, pp. 469- 473 ,(1994) , 10.1097/00004872-199404000-00018
Roberto Sega, Giancarlo Cesana, Camilla Milesi, Guido Grassi, Alberto Zanchetti, Giuseppe Mancia, Ambulatory and Home Blood Pressure Normality in the Elderly Hypertension. ,vol. 30, pp. 1- 6 ,(1997) , 10.1161/01.HYP.30.1.1
Paolo Palatini, Clinical Relevance of Nighttime Blood Pressure and of Daytime Blood Pressure Variability Archives of Internal Medicine. ,vol. 152, pp. 1855- 1860 ,(1992) , 10.1001/ARCHINTE.1992.00400210081013
Jennifer E. Liu, Mary J. Roman, Riccardo Pini, Joseph E. Schwartz, Thomas G. Pickering, Richard B. Devereux, Cardiac and Arterial Target Organ Damage in Adults with Elevated Ambulatory and Normal Office Blood Pressure Annals of Internal Medicine. ,vol. 131, pp. 564- 572 ,(1999) , 10.7326/0003-4819-131-8-199910190-00003