作者: Annika Jahnke , Juergen Gandrass , Wolfgang Ruck
DOI: 10.1016/J.CHROMA.2004.02.060
关键词:
摘要: Reversed-phase LC-MS/MS is used to determine major estrogenic alkylphenol ethoxylates (APEOs) and their biotransformation products. It allows the simultaneous analysis of eight APEOs, alkylphenoxy carboxylates (APECs) alkylphenols (APs) in sewage treatment plant (STP) effluents same extract after solid-phase enrichment on polymeric Oasis HLB. As precursor ions, [APEO + NH4]+, [APEC - H]- [AP were monitored. Instrumental limits detection (LOD) 2-600 pg, corresponding sample concentrations 0.04-12 ng l(-1), without correction for overall method recoveries. Matrix-induced signal suppression during electrospray ionisation (ESI) extraction as well recoveries assessed suitability deuterated surrogates internal standards was evaluated.