Wearable Contact Lens Sensor for Non-Invasive Continuous Monitoring of Intraocular Pressure

作者: Zhiduo Liu , Hongda Chen , Yijun Wang , Huijuan Wu , Weihua Pei

DOI: 10.3390/MI12020108

关键词:

摘要: Intraocular pressure (IOP) is an essential indicator of the diagnosis and treatment of glaucoma. IOP has an apparent physiological rhythm, and it often reaches its peak value at …

参考文章(37)
M. Leonardi, P. Leuenberger, D. Bertrand, A. Bertsch, P. Renaud, A soft contact lens with a MEMS strain gage embedded for intraocular pressure monitoring international conference on solid state sensors actuators and microsystems. ,vol. 2, pp. 1043- 1046 ,(2003) , 10.1109/SENSOR.2003.1216947
Girish Chitnis, Teimour Maleki, Brian Samuels, Louis B. Cantor, Babak Ziaie, A Minimally Invasive Implantable Wireless Pressure Sensor for Continuous IOP Monitoring IEEE Transactions on Biomedical Engineering. ,vol. 60, pp. 250- 256 ,(2013) , 10.1109/TBME.2012.2205248
Guo-Zhen Chen, Ion-Seng Chan, David C.C. Lam, Capacitive contact lens sensor for continuous non-invasive intraocular pressure monitoring Sensors and Actuators A-physical. ,vol. 203, pp. 112- 118 ,(2013) , 10.1016/J.SNA.2013.08.029
Ning Xue, Sung-Pil Chang, Jeong-Bong Lee, A SU-8-Based Microfabricated Implantable Inductively Coupled Passive RF Wireless Intraocular Pressure Sensor IEEE\/ASME Journal of Microelectromechanical Systems. ,vol. 21, pp. 1338- 1346 ,(2012) , 10.1109/JMEMS.2012.2206072
Li Juan Liu, Jun Bo Wang, De Yong Chen, Jian Chen, Non-Invasive Wireless and Passive MEMS Intraocular Pressure Sensor Based on Flexible Substrate Applied Mechanics and Materials. ,vol. 748, pp. 115- 127 ,(2015) , 10.4028/WWW.SCIENTIFIC.NET/AMM.748.115
Matteo Leonardi, Elie M. Pitchon, Arnaud Bertsch, Philippe Renaud, André Mermoud, Wireless contact lens sensor for intraocular pressure monitoring: assessment on enucleated pig eyes. Acta Ophthalmologica. ,vol. 87, pp. 433- 437 ,(2009) , 10.1111/J.1755-3768.2008.01404.X
Amit Todani, Irmgard Behlau, Mark A. Fava, Fabiano Cade, Daniel G. Cherfan, Fouad R. Zakka, Frederick A. Jakobiec, Yuqing Gao, Claes H. Dohlman, Samir A. Melki, Intraocular Pressure Measurement by Radio Wave Telemetry Investigative Ophthalmology & Visual Science. ,vol. 52, pp. 9573- 9580 ,(2011) , 10.1167/IOVS.11-7878
Jeffrey Lin, Yu Zhao, Po-Jui Chen, Mark Humayun, Yu-Chong Tai, Feeling the Pressure: A Parylene-Based Intraocular Pressure Sensor IEEE Nanotechnology Magazine. ,vol. 6, pp. 8- 16 ,(2012) , 10.1109/MNANO.2012.2203876
Jialiang Zhang, Yoshimichi Nagao, Saburo Kuwano, Yoshinori Ito, Microstructure and Temperature Coefficient of Resistance of Platinum Films Japanese Journal of Applied Physics. ,vol. 36, pp. 834- 839 ,(1997) , 10.1143/JJAP.36.834
Young H Kwon, John H Fingert, Markus H Kuehn, Wallace LM Alward, Primary open-angle glaucoma The Lancet. ,vol. 363, pp. 1711- 1720 ,(2004) , 10.1016/S0140-6736(04)16257-0