Determination of erythromycin concentrations in rat plasma and liver by high-performance liquid chromatography with amperometric detection

作者: Erika Hanada , Hisakazu Ohtani , Hajime Kotaki , Yasufumi Sawada , Tatsuji Iga

DOI: 10.1016/S0378-4347(97)00011-X

关键词:

摘要: Abstract A simple method for the quantitative determination of erythromycin (EM) concentrations in rat plasma and liver by high-performance liquid chromatography with amperometric detection was developed. EM extracted from 200 μl or homogenate sample under sodium hydroxide alkaline conditions tert.-butyl methyl ether. Oleandomycin used as an internal standard. The recovery rate up to 100%. detector cell potential oxidation +1100 mV. calibration curves were linear over concentration ranges 0.1–20.0 μg/ml 0.5–100.0 μg/g liver. applied rats after intravenous administration (50 mg/kg dose). presented here has proved be great use investigation pharmacokinetic characteristics small animals such rats.

参考文章(16)
Niels-A. von Rosenstiel, Dieter Adam, Macrolide antibacterials. Drug interactions of clinical significance. Drug Safety. ,vol. 13, pp. 105- 122 ,(1995) , 10.2165/00002018-199513020-00005
Piero Periti, Teresita Mazzei, Enrico Mini, Andrea Novelli, Pharmacokinetic Drug Interactions of Macrolides Clinical Pharmacokinectics. ,vol. 23, pp. 106- 131 ,(1992) , 10.2165/00003088-199223020-00004
Th. Cachet, P. Lannoo, J. Paesen, G. Janssen, J. Hoogmartens, Determination of erythromycin ethylsuccinate by liquid chromatography. Journal of Chromatography A. ,vol. 600, pp. 99- 108 ,(1992) , 10.1016/0021-9673(92)85443-W
David G. Paris, Thomas F. Parente, Humberto R. Bruschetta, Eliscer Guzman, Andreas P. Niarchos, Torsades de pointes induced by erythromycin and terfenadine. American Journal of Emergency Medicine. ,vol. 12, pp. 636- 638 ,(1994) , 10.1016/0735-6757(94)90029-9
C. Stubbs, J.M. Haigh, I. Kanfer, Determination of Erythromycin in Serum and Urine by High-Performance Liquid Chromatography with Ultraviolet Detection Journal of Pharmaceutical Sciences. ,vol. 74, pp. 1126- 1128 ,(1985) , 10.1002/JPS.2600741027
D. Croteau, F. Vallée, M.G. Bergeron, M. LeBel, High-performance liquid chromatographic assay of erythromycin and its esters using electrochemical detection. Journal of Chromatography A. ,vol. 419, pp. 205- 212 ,(1987) , 10.1016/0378-4347(87)80278-5
Michael Ragosta, Albert C. Weihl, Lynda E. Rosenfeld, Potentially fatal interaction between erythromycin and disopyramide The American Journal of Medicine. ,vol. 86, pp. 465- 466 ,(1989) , 10.1016/0002-9343(89)90346-X