Biocompatible enzymatic roller pens for direct writing of biocatalytic materials: "do-it-yourself" electrochemical biosensors.

作者: Amay J. Bandodkar , Wenzhao Jia , Julian Ramírez , Joseph Wang

DOI: 10.1002/ADHM.201400808

关键词:

摘要: The development of enzymatic‐ink‐based roller pens for direct drawing of biocatalytic sensors, in general, and for realizing renewable glucose sensor strips, in particular, is …

参考文章(46)
D. COMBES, M. GRABER, W. N. YE, Stabilizing Effect of Polyhydric Alcohols Annals of the New York Academy of Sciences. ,vol. 613, pp. 559- 563 ,(1990) , 10.1111/J.1749-6632.1990.TB18220.X
Mohammad Taghi Taghizadeh, Abbas Mehrdad, Calculation of the rate constant for the ultrasonic degradation of aqueous solutions of polyvinyl alcohol by viscometry. Ultrasonics Sonochemistry. ,vol. 10, pp. 309- 313 ,(2003) , 10.1016/S1350-4177(03)00110-X
Yu Long Han, Jie Hu, Guy M. Genin, Tian Jian Lu, Feng Xu, BioPen: direct writing of functional materials at the point of care Scientific Reports. ,vol. 4, pp. 4872- 4872 ,(2015) , 10.1038/SREP04872
Ivica Janigová, Igor Lacı́k, Ivan Chodák, Thermal degradation of plasticized poly(3-hydroxybutyrate) investigated by DSC Polymer Degradation and Stability. ,vol. 77, pp. 35- 41 ,(2002) , 10.1016/S0141-3910(02)00077-0
Joseph Wang, Abdel-Nasser Kawde, Amplified label-free electrical detection of DNA hybridization Analyst. ,vol. 127, pp. 383- 386 ,(2002) , 10.1039/B110821M
K. Fukushima, C. Abbate, D. Tabuani, M. Gennari, G. Camino, Biodegradation of poly(lactic acid) and its nanocomposites. Polymer Degradation and Stability. ,vol. 94, pp. 1646- 1655 ,(2009) , 10.1016/J.POLYMDEGRADSTAB.2009.07.001
Tamoghna Bhattacharyya, Sarbani Samaddar, Anjan Kr. Dasgupta, Reusable glucose sensing using carbon nanotube-based self-assembly Nanoscale. ,vol. 5, pp. 9231- 9237 ,(2013) , 10.1039/C3NR02609D
Jeffrey D. Newman, Anthony P.F. Turner, Home blood glucose biosensors: a commercial perspective Biosensors and Bioelectronics. ,vol. 20, pp. 2435- 2453 ,(2005) , 10.1016/J.BIOS.2004.11.012
Nicolò Dossi, Rosanna Toniolo, Fabio Terzi, Flavia Impellizzieri, Gino Bontempelli, Pencil leads doped with electrochemically deposited Ag and AgCl for drawing reference electrodes on paper-based electrochemical devices Electrochimica Acta. ,vol. 146, pp. 518- 524 ,(2014) , 10.1016/J.ELECTACTA.2014.09.049
Joseph Wang, Amperometric biosensors for clinical and therapeutic drug monitoring: a review. Journal of Pharmaceutical and Biomedical Analysis. ,vol. 19, pp. 47- 53 ,(1999) , 10.1016/S0731-7085(98)00056-9