Radiation-enhanced field-forced deposition of a laser-produced aerosol in a graphite furnace and continuum-source coherent forward scattering multi-element determination

作者: Gerd M. Hermann , George F. Lasnitschka , Ralph Moder , Thomas W. Szardening

DOI: 10.1039/JA9920700457

关键词:

摘要: An aerosol produced by laser ablation was transported into a graphite furnace with the inert gas flow and deposited after α-irradiation without an additional electric field of different polarity applied inside furnace. Using Nd:YAG pulsed at rate several kHz for each pulse about 20 ns duration, 300 kW peak power detection coherent forward scattering spectrometry in combination xenon continuum source, multi-element spectra analyte were recorded. The intensities measured on 283.1 nm line lead detected brass as function number pulses yielding analytical curves. Field enhancement deposition factor 103 found. capability spectrometric approach source allows use internal standards.

参考文章(10)
R. Wennrich, K. Dittrich, Laser ablation for aerosol deposition graphite furnace atomic absorption spectrometry Spectrochimica Acta Part B: Atomic Spectroscopy. ,vol. 42, pp. 995- 1004 ,(1987) , 10.1016/0584-8547(87)80111-8
M. Ito, S. Murayama, K. Kayama, M. Yamamoto, The detection of cadmium by employing the forward scattering of resonance radiation Spectrochimica Acta Part B: Atomic Spectroscopy. ,vol. 32, pp. 347- 355 ,(1977) , 10.1016/0584-8547(77)80022-0
Kichinosuke Hirokawa, Michiko Namiki, Coherent forward scattering spectrometry of manganese and chromium using a xenon lamp and a tellurous oxide acousto-optic tunable filter Spectrochimica Acta Part B: Atomic Spectroscopy. ,vol. 37, pp. 165- 170 ,(1982) , 10.1016/0584-8547(82)80054-2
Gurvinder S. Jolly, Roger Stephens, Multi-channel measurements by non-dispersive magneto-optic rotation Spectrochimica Acta Part B: Atomic Spectroscopy. ,vol. 39, pp. 335- 342 ,(1984) , 10.1016/0584-8547(84)80040-3
W. Grimm, G. Hermann, M. Jung, R. Krüger, G. Lasnitschka, A. Scharmann, M. Seib, Coherent forward scattering spectrometry by means of a commercial furnace electromagnet unit Spectrochimica Acta Part B: Atomic Spectroscopy. ,vol. 43, pp. 1269- 1272 ,(1988) , 10.1016/0584-8547(88)80169-1
L. A. Davis, J. D. Winefordner, Evaluation of a Voigt effect coherent forward scattering atomic spectrometer Analytical Chemistry. ,vol. 59, pp. 309- 312 ,(1987) , 10.1021/AC00129A019
G. Hermann, M. Jung, G. Lasnitschka, R. Moder, A. Scharmann, X. Zhou, Multielement determination on strong and weak lines by coherent forward scattering spectroscopy with continuum sources Spectrochimica Acta Part B: Atomic Spectroscopy. ,vol. 45, pp. 763- 768 ,(1990) , 10.1016/0584-8547(90)80055-N
A.D. Kersey, J.B. Dawson, D.J. Ellis, The contributions of magnetically induced dichroism and the resonant Voigt effect to the detection of silver by atomic spectroscopy Spectrochimica Acta Part B: Atomic Spectroscopy. ,vol. 35, pp. 865- 873 ,(1980) , 10.1016/0584-8547(80)80024-3
Thomas C. O'Haver, James M. Harnly, John Marshall, John Carroll, David Littlejohn, John M. Ottaway, A microcomputer-controlled background correction system for atomic spectrometry Analyst. ,vol. 110, pp. 451- 458 ,(1985) , 10.1039/AN9851000451