A microdialysis technique for continuous subcutaneous glucose monitoring in diabetic patients (part 1)

作者: A Poscia , M Mascini , D Moscone , M Luzzana , G Caramenti

DOI: 10.1016/S0956-5663(02)00216-6

关键词:

摘要: The performances and the stability of a novel subcutaneous glucose monitoring system have been evaluated. GlucoDay (A. Menarini I.F.R. S.r.l, Florence Italy) is portable instrument provided with micro-pump biosensor coupled to microdialysis capable recording level every 3 min. Long short term are discussed results some critical in vitro vivo (on rabbits) experiments reported. A linear response up 30 mM has found for concentration. sensitivity referred blood better than 0.1 zero current typically below equivalent mM. In accuracy study mean bias 2.7 mg/dl correlation coefficient equal 0.9697 found. At room temperature, an excellent membrane assures good 6 months from first use.

参考文章(17)
D. Moscone, M. Mascini, In Vivo Monitoring with Microdialysis Probe Springer, Dordrecht. pp. 115- 122 ,(1993) , 10.1007/978-94-011-1932-0_11
Anthony Turner, Prospects for in vivo sensing 22nd Romanian Congress of Diabetes. ,(1996)
Girish Rao, Peretz Glikfeld, Richard H. Guy, Reverse iontophoresis : development of a noninvasive approach for glucose monitoring Pharmaceutical Research. ,vol. 10, pp. 1751- 1755 ,(1993) , 10.1023/A:1018926215306
Moscone D, Mascini M, Microdialysis and glucose biosensor for in vivo monitoring. Annales De Biologie Clinique. ,vol. 50, pp. 323- 327 ,(1992)
Valérie Thomé-Duret, Gérard Reach, Marie Noèlle Gangnerau, Fabrice Lemonnier, Jean Claude Klein, Yanan Zhang, Yibai Hu, George S Wilson, None, Use of a subcutaneous glucose sensor to detect decreases in glucose concentration prior to observation in blood. Analytical Chemistry. ,vol. 68, pp. 3822- 3826 ,(1996) , 10.1021/AC960069I
Wolfgang Kerner, Martin Kiwit, Burkhard Linke, Fritz S. Keck, Horst Zier, Ernst F. Pfeiffer, The function of a hydrogen peroxide-detecting electroenzymatic glucose electrode is markedly impaired in human sub-cutaneous tissue and plasma Biosensors and Bioelectronics. ,vol. 8, pp. 473- 482 ,(1993) , 10.1016/0956-5663(93)80032-K
Kenneth J. Ward, David M. Haaland, M. Ries Robinson, R. Philip Eaton, Post-Prandial Blood Glucose Determination by Quantitative Mid-Infrared Spectroscopy Applied Spectroscopy. ,vol. 46, pp. 959- 965 ,(1992) , 10.1366/0003702924124493
S. K. Garg, R. O. Potts, N. R. Ackerman, S. J. Fermi, J. A. Tamada, H. P. Chase, Correlation of fingerstick blood glucose measurements with GlucoWatch biographer glucose results in young subjects with type 1 diabetes. Diabetes Care. ,vol. 22, pp. 1708- 1714 ,(1999) , 10.2337/DIACARE.22.10.1708
Isao Karube, Anthony PF Turner, George S Wilson, None, Biosensors: fundamentals and applications Analytica Chimica Acta. ,vol. 201, pp. 363- 364 ,(1987) , 10.1016/S0003-2670(00)85361-1