Locking compression plate and cerclage band for type B1 periprosthetic femoral fractures preliminary results at average 30-month follow-up.

作者: Huaming Xue , Yihui Tu , Minwei Cai , Anli Yang

DOI: 10.1016/J.ARTH.2010.03.031

关键词:

摘要: We present results of 12 type B1 periprosthetic femoral fractures treated with locking compression plate and cerclage band from January 2003 to June 2007. The average follow-up was 30.1 months. Twelve united in an period 4.8 mean Harris hip score 84.4. One patient presented loosening proximal screws at 5 This nonoperatively as she had radiographic evidence fracture union. delayed union required 9 months heal. Unfortunately, 1 month later, sustained a C during slipping injury cast immobilization. after 4 None complications loss reduction, break, wound infection.

参考文章(34)
Daniel J. Berry, Epidemiology: hip and knee. Orthopedic Clinics of North America. ,vol. 30, pp. 183- 190 ,(1999) , 10.1016/S0030-5898(05)70073-0
Hans Lindahl, Henrik Malchau, Peter Herberts, Göran Garellick, Periprosthetic Femoral Fractures The Journal of Arthroplasty. ,vol. 20, pp. 857- 865 ,(2005) , 10.1016/J.ARTH.2005.02.001
FARES S. HADDAD, CLIVE P. DUNCAN, DANIEL J. BERRY, DAVID G. LEWALLEN, ALLAN E. GROSS, HUGH P. CHANDLER, Periprosthetic femoral fractures around well-fixed implants: Use of cortical onlay allografts with or without a plate Journal of Bone and Joint Surgery, American Volume. ,vol. 84, pp. 945- 950 ,(2002) , 10.2106/00004623-200206000-00008
T.S.F. Tadross, A.M. Nanu, M.J. Buchanan, R.G. Checketts, Dall-Miles plating for periprosthetic B1 fractures of the femur. Journal of Arthroplasty. ,vol. 15, pp. 47- 51 ,(2000) , 10.1016/S0883-5403(00)91129-X
Jagannath Chakravarthy, Rajeev Bansal, Julian Cooper, Locking plate osteosynthesis for Vancouver Type B1 and Type C periprosthetic fractures of femur: a report on 12 patients. Injury-international Journal of The Care of The Injured. ,vol. 38, pp. 725- 733 ,(2007) , 10.1016/J.INJURY.2007.02.038
Owen H. Brady, Donald S. Garbuz, Bassam A. Masri, Clive P. Duncan, The reliability of validity of the Vancouver classification of femoral fractures after hip replacement Journal of Arthroplasty. ,vol. 15, pp. 59- 62 ,(2000) , 10.1016/S0883-5403(00)91181-1
Paul Wong, Allan E. Gross, The use of structural allografts for treating periprosthetic fractures about the hip and knee. Orthopedic Clinics of North America. ,vol. 30, pp. 259- 264 ,(1999) , 10.1016/S0030-5898(05)70080-8
Eric Fulkerson, Kenneth Koval, Charles F Preston, Kazuho Iesaka, Frederick J Kummer, Kenneth A Egol, Fixation of periprosthetic femoral shaft fractures associated with cemented femoral stems : A biomechanical comparison of locked plating and conventional cable plates Journal of Orthopaedic Trauma. ,vol. 20, pp. 89- 93 ,(2006) , 10.1097/01.BOT.0000199119.38359.96