Limb/Trunk Lean Mass Ratio as a Risk Factor for Mortality in Peritoneal Dialysis Patients

作者: Seok Hui Kang , Jong Won Park , Kyung Woo Yoon , Jun Young Do

DOI: 10.1053/J.JRN.2012.09.004

关键词:

摘要: Background This study was performed to determine the clinical relevance of limb/trunk lean mass ratio (LTLM) in continuous ambulatory peritoneal dialysis (CAPD) patients. Methods retrospective cohort included 534 CAPD Body compositions were measured using a dual-energy X-ray absorptiometry apparatus. Results In males, sensitivity and specificity for diagnosis sarcopenia 70.3% 85.9%, respectively. Respective values females 62.3% 83.8%. The initial low LTLM tertile associated with mortality male patients female Among who maintained year, maintenance mortality. Conclusions is other indices, nutritional status, Therefore, novel marker that useful prediction status CAPD.

参考文章(31)
José Abrão Cardeal da Costa, T. Alp Ikizler, Inflammation and insulin resistance as novel mechanisms of wasting in chronic dialysis patients. Seminars in Dialysis. ,vol. 22, pp. 652- 657 ,(2009) , 10.1111/J.1525-139X.2009.00664.X
Matthew J Delmonico, Tamara B Harris, Jung‐Sun Lee, Marjolein Visser, Michael Nevitt, Stephen B Kritchevsky, Frances A Tylavsky, Anne B Newman, Health, Aging and Body Composition Study, Alternative definitions of sarcopenia, lower extremity performance, and functional impairment with aging in older men and women Journal of the American Geriatrics Society. ,vol. 55, pp. 769- 774 ,(2007) , 10.1111/J.1532-5415.2007.01140.X
R Roubenoff, J J Kehayias, B Dawson-Hughes, S B Heymsfield, Use of dual-energy x-ray absorptiometry in body-composition studies: not yet a "gold standard". The American Journal of Clinical Nutrition. ,vol. 58, pp. 589- 591 ,(1993) , 10.1093/AJCN/58.5.589
O L Svendsen, J Haarbo, C Hassager, C Christiansen, Accuracy of measurements of body composition by dual-energy x-ray absorptiometry in vivo. The American Journal of Clinical Nutrition. ,vol. 57, pp. 605- 608 ,(1993) , 10.1093/AJCN/57.5.605
Jonas Bergström, Olof Heimbürger, Bengt Lindholm, Calculation of the Protein Equivalent of Total Nitrogen Appearance from Urea Appearance. Which Formulas Should be Used Peritoneal Dialysis International. ,vol. 18, pp. 467- 473 ,(1998) , 10.1177/089686089801800502
Doris I. Stenver, Anders Gotfredsern, Jannik Hilsted, Bent Nielsen, Body Composition in Hemodialysis Patients Measured by Dual-Energy X-Ray Absorptiometry American Journal of Nephrology. ,vol. 15, pp. 105- 110 ,(1995) , 10.1159/000168812
A. Kato, Influence of body composition on 5 year mortality in patients on regular haemodialysis Nephrology Dialysis Transplantation. ,vol. 18, pp. 333- 340 ,(2003) , 10.1093/NDT/18.2.333
Antje Fürstenberg, Andrew Davenport, Assessment of body composition in peritoneal dialysis patients using bioelectrical impedance and dual-energy x-ray absorptiometry. American Journal of Nephrology. ,vol. 33, pp. 150- 156 ,(2011) , 10.1159/000324111
Lindsay D Plank, Dual-energy X-ray absorptiometry and body composition. Current Opinion in Clinical Nutrition and Metabolic Care. ,vol. 8, pp. 305- 309 ,(2005) , 10.1097/01.MCO.0000165010.31826.3D
Erwin Fleischmann, Nancy Teal, John Dudley, Warren May, John D. Bower, Abdulla K. Salahudeen, Influence of excess weight on mortality and hospital stay in 1346 hemodialysis patients. Kidney International. ,vol. 55, pp. 1560- 1567 ,(1999) , 10.1046/J.1523-1755.1999.00389.X