Dual energy x-ray absorptiometry of implanted femora after cemented and press-fit total hip arthroplasty in a canine model.

作者: Mark D. Markel , F. Gottsauner-Wolf , John J. Bogdanske , Heinz W. Wahner , Edmund Y. S. Chao

DOI: 10.1002/JOR.1100110319

关键词:

摘要: The effect of a press-fit and cemented titanium alloy endoprosthesis on the measurement bone mineral density (BMD) proximal femur in canine model with dual energy x-ray absorptiometry (DXA) was determined. Seven regions interest, corresponding to zones 1-7 according Gruen et al., were measured. Eight unpaired femora scanned DXA before implantation (five separate scans per femur), after press-fitting femoral component femur); cementing same femur). When press-fit, BMD five seven increased significantly (range, 2.7-23.1%; mean, 11.2%), although mean precision error this not altered (before implantation, 1.1%; 1.8%). Cementing implant caused variable BMD, resulting decrease distal where cortical relatively thin compared cement mantle (regions 3, 4, 5) an increase other regions. 7.2% 1.1-12.6%).

参考文章(13)
HEINZ W. WAHNER, WILLIAM L. DUNN, MANUEL L. BROWN, RICHARD L. MORIN, B. LAWRENCE RIGGS, Comparison of dual-energy x-ray absorptiometry and dual photon absorptiometry for bone mineral measurements of the lumbar spine. Mayo Clin., Proc.; (United States). ,vol. 63, pp. 1075- 1084 ,(1988) , 10.1016/S0025-6196(12)65502-5
J. Lilley, B. G. Walters, D. A. Heath, Z. Drolc, In vivo and in vitro precision for bone density measured by dual-energy X-ray absorption. Osteoporosis International. ,vol. 1, pp. 141- 146 ,(1991) , 10.1007/BF01625443
J. DENNIS BOBYN, ERROL S. MORTIMER, ANDREW H. GLASSMAN, CHARLES A. ENGH, JOSEPH E. MILLER, C. EMERSON BROOKS, Producing and avoiding stress shielding. Laboratory and clinical observations of noncemented total hip arthroplasty Clinical Orthopaedics and Related Research. ,vol. 274, pp. 79- 96 ,(1992) , 10.1097/00003086-199201000-00010
THOMAS A. GRUEN, GREGORY M. MCNEICE, HARLAN C. AMSTUTZ, "Modes of failure" of cemented stem-type femoral components: a radiographic analysis of loosening. Clinical Orthopaedics and Related Research. ,vol. 141, pp. 17- 27 ,(1979) , 10.1097/00003086-197906000-00002
Douglas D. Robertson, Peter J. Weiss, Elliot K. Fishman, Donna Magid, Peter S. Walker, Evaluation of CT techniques for reducing artifacts in the presence of metallic orthopedic implants. Journal of Computer Assisted Tomography. ,vol. 12, pp. 236- 241 ,(1988) , 10.1097/00004728-198803000-00012
FW Reckling, MA Asher, WL Dillon, A longitudinal study of the radiolucent line at the bone-cement interface following total joint-replacement procedures Journal of Bone and Joint Surgery, American Volume. ,vol. 59, pp. 355- 358 ,(1977) , 10.2106/00004623-197759030-00011
CK McCarthy, GG Steinberg, M Agren, D Leahey, E Wyman, DT Baran, Quantifying bone loss from the proximal femur after total hip arthroplasty Journal of Bone and Joint Surgery-british Volume. ,vol. 73, pp. 774- 778 ,(1991) , 10.1302/0301-620X.73B5.1894664
W H Harris, J C McCarthy, D A OʼNeill, Femoral component loosening using contemporary techniques of femoral cement fixation. The Journal of Bone & Joint Surgery. ,vol. 64, pp. 1063- 1067 ,(1982) , 10.2106/00004623-198264070-00017
MARK D. MARKEL, The Power of a Statistical Test What Does Insignificance Mean Veterinary Surgery. ,vol. 20, pp. 209- 214 ,(1991) , 10.1111/J.1532-950X.1991.TB00336.X