Short T2 contrast with three-dimensional ultrashort echo time imaging

作者: Jiang Du , Mark Bydder , Atsushi M. Takahashi , Michael Carl , Christine B. Chung

DOI: 10.1016/J.MRI.2010.11.003

关键词:

摘要: There is increasing interest in imaging short T2 species which show little or no signal with conventional magnetic resonance (MR) pulse sequences. In this paper, we describe the use of three-dimensional ultrashort echo time (3D UTE) sequences TEs down to 8 μs for these species. Image contrast was generated acquisitions using dual 3D UTE subtraction, rescaled long saturation UTE, single adiabatic inversion recovery subtraction and UTE. The feasibility approaches demonstrated vitro vivo calcified cartilage, aponeuroses, menisci, tendons, ligaments cortical bone a 3-T clinical MR scanner. Signal-to-noise ratios contrast-to-noise were used compare techniques.

参考文章(28)
Kevin M. Johnson, Darren P. Lum, Patrick A. Turski, Walter F. Block, Charles A. Mistretta, Oliver Wieben, Improved 3D Phase Contrast MRI with Off-resonance Corrected Dual Echo VIPR Magnetic Resonance in Medicine. ,vol. 60, pp. 1329- 1336 ,(2008) , 10.1002/MRM.21763
Matthew D. Robson, Peter D. Gatehouse, Mark Bydder, Graeme M. Bydder, Magnetic resonance: an introduction to ultrashort TE (UTE) imaging. Journal of Computer Assisted Tomography. ,vol. 27, pp. 825- 846 ,(2003) , 10.1097/00004728-200311000-00001
Garry E. Gold, John M. Pauly, Albert Macovski, Robert J. Herfkens, MR Spectroscopic imaging of collagen: Tendons and knee menisci Magnetic Resonance in Medicine. ,vol. 34, pp. 647- 654 ,(1995) , 10.1002/MRM.1910340502
C J Bergin, J M Pauly, A Macovski, Lung parenchyma: projection reconstruction MR imaging. Radiology. ,vol. 179, pp. 777- 781 ,(1991) , 10.1148/RADIOLOGY.179.3.2027991
Jiang Du, Gavin Hamilton, Atsushi Takahashi, Mark Bydder, Christine B. Chung, Ultrashort echo time spectroscopic imaging (UTESI) of cortical bone. Magnetic Resonance in Medicine. ,vol. 58, pp. 1001- 1009 ,(2007) , 10.1002/MRM.21397
M.S Silver, R.I Joseph, D.I Hoult, Highly selective and π pulse generation Journal of Magnetic Resonance (1969). ,vol. 59, pp. 347- 351 ,(1984) , 10.1016/0022-2364(84)90181-1
Andrew V. Barger, Walter F. Block, Yuriy Toropov, Thomas M. Grist, Charles A. Mistretta, Time-resolved contrast-enhanced imaging with isotropic resolution and broad coverage using an undersampled 3D projection trajectory Magnetic Resonance in Medicine. ,vol. 48, pp. 297- 305 ,(2002) , 10.1002/MRM.10212
John I. Jackson, Dwight G. Nishimura, Albert Macovski, Twisting radial lines with application to robust magnetic resonance imaging of irregular flow. Magnetic Resonance in Medicine. ,vol. 25, pp. 128- 139 ,(1992) , 10.1002/MRM.1910250113
Greg J. Stanisz, Ewa E. Odrobina, Joseph Pun, Michael Escaravage, Simon J. Graham, Michael J. Bronskill, R. Mark Henkelman, T1, T2 relaxation and magnetization transfer in tissue at 3T Magnetic Resonance in Medicine. ,vol. 54, pp. 507- 512 ,(2005) , 10.1002/MRM.20605