A Simple Electrochemical Aptamer Cytosensor for Direct Detection of Chronic Myelogenous Leukemia K562 Cells

作者: Tianxiao Yu , Hui Zhang , Zhenglan Huang , Zhenhong Luo , Ningshu Huang

DOI: 10.1002/ELAN.201600505

关键词:

摘要: A simple and rapid electrochemical aptamer cytosensor has been developed for direct detection of chronic myelogenous leukemia (CML) K562 cells based on a specific biotin conjugated concanavalin (bio-ConA) probe. The cell could be specifically recognized by T2-KK1B10 capture pre-immobilized gold modified electrode surface. Then, bio-ConA was added in the reaction to identify surface mannose, resulting an aptamer-K562 cell-bio-ConA sandwich complex. Finally, streptavidin alkaline phosphatase (ST-ALP) combined with catalyze α-naphthyl (α-NP) phosphate form α-naphthol which is highly electroactive at operating voltage 180 mV (vs. Ag/AgCl). Under optimum conditions, DPV signals were proportional logarithm from 1×102 1×107 cells mL−1 limit 79 cells mL−1. also exhibited high selectivity, stability reproducibility. When applied detect human blood samples, recoveries between 79.6 %–93.3 % obtained, indicating biosensor would potential alternative tool CML real biological samples.

参考文章(36)
Xueping Chen, Li Wang, Shangchun Sheng, Teng Wang, Juan Yang, Guoming Xie, Wenli Feng, Coupling a universal DNA circuit with graphene sheets/polyaniline/AuNPs nanocomposites for the detection of BCR/ABL fusion gene. Analytica Chimica Acta. ,vol. 889, pp. 90- 97 ,(2015) , 10.1016/J.ACA.2015.06.050
Chunmei Yu, Qiuhong Wang, Weibo Li, Yubin Li, Shuxian Liu, Ning Bao, Haiying Gu, Paper-based cell impedance sensor and its application for cytotoxic evaluation Nanotechnology. ,vol. 26, pp. 325501- ,(2015) , 10.1088/0957-4484/26/32/325501
Fuad El Rassi, John D. Bergsagel, Martha Arellano, Manila Gaddh, Anand Jillella, Vamsi Kota, Leonard T. Heffner, Elliott F. Winton, Hanna Jean Khoury, Predicting early blast transformation in chronic-phase chronic myeloid leukemia: Is immunophenotyping the missing link? Cancer. ,vol. 121, pp. 872- 875 ,(2015) , 10.1002/CNCR.29142
Sun Tee Tay, A.S.S. Anuar, Investigation on the conA binding properties of Klebsiella pneumoniae. Tropical Biomedicine. ,vol. 31, pp. 802- 812 ,(2014)
Nianxi Zhao, Sung-Nan Pei, Jianjun Qi, Zihua Zeng, Swaminathan P. Iyer, Pei Lin, Ching-Hsuan Tung, Youli Zu, Oligonucleotide aptamer-drug conjugates for targeted therapy of acute myeloid leukemia. Biomaterials. ,vol. 67, pp. 42- 51 ,(2015) , 10.1016/J.BIOMATERIALS.2015.07.025
Tianshu Wang, Jiyang Liu, Xiaoxiao Gu, Dan Li, Jin Wang, Erkang Wang, Label-free electrochemical aptasensor constructed by layer-by-layer technology for sensitive and selective detection of cancer cells Analytica Chimica Acta. ,vol. 882, pp. 32- 37 ,(2015) , 10.1016/J.ACA.2015.05.008
R Hehlmann, H Heimpel, J Hasford, HJ Kolb, H Pralle, DK Hossfeld, W Queisser, H Loffler, A Hochhaus, B Heinze, Randomized comparison of interferon-alpha with busulfan and hydroxyurea in chronic myelogenous leukemia. The German CML Study Group [see comments] Blood. ,vol. 84, pp. 4064- 4077 ,(1994) , 10.1182/BLOOD.V84.12.4064.BLOODJOURNAL84124064
Zsuzsanna Szeitner, Judit András, Róbert E. Gyurcsányi, Tamás Mészáros, Is less more? Lessons from aptamer selection strategies Journal of Pharmaceutical and Biomedical Analysis. ,vol. 101, pp. 58- 65 ,(2014) , 10.1016/J.JPBA.2014.04.018
Pinhua Lei, Hua Tang, Shijia Ding, Xiaojuan Ding, Dan Zhu, Bo Shen, Quan Cheng, Yurong Yan, Determination of the invA gene of Salmonella using surface plasmon resonance along with streptavidin aptamer amplification Microchimica Acta. ,vol. 182, pp. 289- 296 ,(2015) , 10.1007/S00604-014-1330-6
Kwame Sefah, ZW Tang, DH Shangguan, Hui Chen, Dalia Lopez-Colon, Ying Li, Parag Parekh, Jennifer Martin, Ling Meng, JA Phillips, YM Kim, WH Tan, None, Molecular recognition of acute myeloid leukemia using aptamers. Leukemia. ,vol. 23, pp. 235- 244 ,(2009) , 10.1038/LEU.2008.335