Image quality and dose management in digital radiography: a new paradigm for optimisation

作者: H. P. Busch , K. Faulkner

DOI: 10.1093/RPD/NCI728

关键词:

摘要: The advent of digital imaging in radiology, combined with the explosive growth technology, has dramatically improved techniques. This led to expansion diagnostic capabilities, both terms number procedures and their scope. Throughout world, film/screen radiography systems are being rapidly replaced systems. Many progressive medical institutions have acquired, or considering purchase computed strorage phosphor plates direct flat panel detectors. However, unknown some users, these devices offer a new paradigm opportunity challenges. Images can be obtained at lower dose owing higher detective quantum efficiency (DQE). These fundamental differences comparison conventional film/screens necessitate development strategies for quality optimisations. A set referral criteria based upon three levels is proposed.

参考文章(16)
H.P. Busch, Need for New Optimisation Strategies in CR and Direct Digital Radiography Radiation Protection Dosimetry. ,vol. 90, pp. 31- 33 ,(2000) , 10.1093/OXFORDJOURNALS.RPD.A033139
Carey E. Floyd, Richard J. Warp, James T. Dobbins, Harrell G. Chotas, Alan H. Baydush, Rene Vargas-Voracek, Carl E. Ravin, Imaging characteristics of an amorphous silicon flat-panel detector for digital chest radiography. Radiology. ,vol. 218, pp. 683- 688 ,(2001) , 10.1148/RADIOLOGY.218.3.R01FE45683
Terue Okamura, Saori Tanaka, Koichi Koyama, Nishida Norihumi, Hideo Daikokuya, Toshiyuki Matsuoka, Kenji Kishimoto, Masakatsu Hatagawa, Hiroaki Kudoh, Ryusaku Yamada, Clinical evaluation of digital radiography based on a large-area cesium iodide-amorphous silicon flat-panel detector compared with screen-film radiography for skeletal system and abdomen European Radiology. ,vol. 12, pp. 1741- 1747 ,(2002) , 10.1007/S00330-001-1283-0
Ulrich Neitzel, Albrecht Boehm, Ingo Maack, Comparison of low-contrast detail detectability with five different conventional and digital radiographic imaging systems Medical Imaging 2000: Image Perception and Performance. ,vol. 3981, pp. 216- 223 ,(2000) , 10.1117/12.383113
Jan Persliden, K.-W. Beckman, H. Geijer, T. Andersson, Dose-image optimisation in digital radiology with a direct digital detector: an example applied to pelvic examinations European Radiology. ,vol. 12, pp. 1584- 1588 ,(2002) , 10.1007/S00330-001-1206-0
M Strotzer, J Gmeinwieser, M Völk, R Fründ, J Seitz, C Manke, H Albrich, S Feuerbach, Clinical application of a flat-panel X-ray detector based on amorphous silicon technology: image quality and potential for radiation dose reduction in skeletal radiography. American Journal of Roentgenology. ,vol. 171, pp. 23- 27 ,(1998) , 10.2214/AJR.171.1.9648757
Tae Sung Kim, Jung-Gi Im, Jin Mo Goo, Kyoung Ho Lee, Yu-Jin Lee, Se Hyung Kim, Seonwoo Kim, Detection of Pulmonary Edema in Pigs: Storage Phosphor versus Amorphous Selenium-based Flat-Panel-Detector Radiography Radiology. ,vol. 223, pp. 695- 701 ,(2002) , 10.1148/RADIOL.2233011079
David J. Brenner, Carl D. Elliston, Eric J. Hall, Walter E. Berdon, Estimated Risks of Radiation-Induced Fatal Cancer from Pediatric CT American Journal of Roentgenology. ,vol. 176, pp. 289- 296 ,(2001) , 10.2214/AJR.176.2.1760289