Determination of glyphosate and AMPA on polyester-toner electrophoresis microchip with contactless conductivity detection.

作者: Eduardo R. da Silva , Thiago P. Segato , Wendell K. T. Coltro , Renato S. Lima , Emanuel Carrilho

DOI: 10.1002/ELPS.201200588

关键词:

摘要: This paper reports a method for rapid, simple, direct, and reproducible determination of glyphosate its major metabolite aminomethylphosphonic acid (AMPA). The platform described herein uses polyester-toner microchips incorporating capacitively coupled contactless conductivity detection electrophoresis separation the analytes. microchip presented 150 μm-wide 12 μm-deep microchannels, with injection lengths 10 40 mm long, respectively. best results were obtained 320 kHz frequency, 4.5 Vpp excitation voltage, 80 mmol/L CHES/Tris buffer at pH 8.8, in -1.0 kV 7 s, -1.5 kV. RSD values related to peak areas AMPA 1.5 3.3% 10.1 8.6% intra- interchip assays, limits 45.1 70.5 μmol/L, respectively, without any attempt preconcentration Finally, was applied river water samples which (1.0 each) added. recovery 87.4 83.7% AMPA, percentages LOD here similar others reported literature.

参考文章(34)
Lee Goodwin, Melissa Hanna, James R. Startin, Brendan J. Keely, David M. Goodall, Isotachophoretic separation of glyphosate, glufosinate, AMPA and MPP with contactless conductivity detection Analyst. ,vol. 127, pp. 204- 206 ,(2002) , 10.1039/B110665C
Gabriela R. M. Duarte, Wendell K. T. Coltro, Juliane C. Borba, Carol W. Price, James P. Landers, Emanuel Carrilho, Disposable polyester–toner electrophoresis microchips for DNA analysis Analyst. ,vol. 137, pp. 2692- 2698 ,(2012) , 10.1039/C2AN16220B
Yujie Sun, Chengyin Wang, Qunyin Wen, Guoxiu Wang, Honghai Wang, Qishu Qu, Xiaoya Hu, None, Determination of Glyphosate and Aminomethylphosphonic Acid in Water by LC Using a New Labeling Reagent, 4-Methoxybenzenesulfonyl Fluoride Chromatographia. ,vol. 72, pp. 679- 686 ,(2010) , 10.1365/S10337-010-1705-8
Wendell Karlos Tomazelli Coltro, Susan M. Lunte, Emanuel Carrilho, Comparison of the analytical performance of electrophoresis microchannels fabricated in PDMS, glass, and polyester-toner. Electrophoresis. ,vol. 29, pp. 4928- 4937 ,(2008) , 10.1002/ELPS.200700897
Wendell K Tomazelli Coltro, José A Fracassi da Silva, Heron D Torres da Silva, Eduardo M Richter, Rogério Furlan, Lúcio Angnes, Claudimir L do Lago, Luiz H Mazo, Emanuel Carrilho, Electrophoresis microchip fabricated by a direct-printing process with end-channel amperometric detection. Electrophoresis. ,vol. 25, pp. 3832- 3839 ,(2004) , 10.1002/ELPS.200406091
Chien-Hsiung Tsai, Ruey-Jen Yang, Chang-Hsien Tai, Lung-Ming Fu, Numerical simulation of electrokinetic injection techniques in capillary electrophoresis microchips. Electrophoresis. ,vol. 26, pp. 674- 686 ,(2005) , 10.1002/ELPS.200410032
B.C. Barja, J. Herszage, M. dos Santos Afonso, Iron(III)–phosphonate complexes Polyhedron. ,vol. 20, pp. 1821- 1830 ,(2001) , 10.1016/S0277-5387(01)00741-0
Gabriela R. M. Duarte, Carol W. Price, Brian H. Augustine, Emanuel Carrilho, James P. Landers, Dynamic Solid Phase DNA Extraction and PCR Amplification in Polyester-Toner Based Microchip Analytical Chemistry. ,vol. 83, pp. 5182- 5189 ,(2011) , 10.1021/AC200292M