Achieving the full performance of highly efficient columns by optimizing conventional benchmark high-performance liquid chromatography instruments.

作者: Fabrice Gritti , Carl A. Sanchez , Tivadar Farkas , Georges Guiochon

DOI: 10.1016/J.CHROMA.2010.02.044

关键词:

摘要: … 100 mm columns packed with 2.6 μ m superficially porous Kinetex-C 18 particles at flow rates of … (26), if we assume a plate height of 3.4 μ m for the Kinetex-C 18 packed columns (ie, a …

参考文章(16)
Henri Colin, Michel Martin, Georges Guiochon, Extra-column effects in high-performance liquid chromatography Journal of Chromatography A. ,vol. 185, pp. 79- 95 ,(1979) , 10.1016/S0021-9673(00)85599-5
Fabrice Gritti, Georges Guiochon, Performance of new prototype packed columns for very high pressure liquid chromatography. Journal of Chromatography A. ,vol. 1217, pp. 1485- 1495 ,(2010) , 10.1016/J.CHROMA.2009.12.057
Shigeharu Katsuo, Christian Langel, Patrick Schanen, Marco Mazzotti, Extra-column dead volume in simulated moving bed separations: theory and experiments. Journal of Chromatography A. ,vol. 1216, pp. 1084- 1093 ,(2009) , 10.1016/J.CHROMA.2008.12.031
Joseph J. Kirkland, Controlled surface porosity supports for high-speed gas and liquid chromatography Analytical Chemistry. ,vol. 41, pp. 218- 220 ,(1969) , 10.1021/AC60270A054
Fabrice Gritti, Irene Leonardis, David Shock, Paul Stevenson, Andrew Shalliker, Georges Guiochon, Performance of columns packed with the new shell particles, Kinetex-C18. Journal of Chromatography A. ,vol. 1217, pp. 1589- 1603 ,(2010) , 10.1016/J.CHROMA.2009.12.079
Fabrice Gritti, Georges Guiochon, The ultimate band compression factor in gradient elution chromatography. Journal of Chromatography A. ,vol. 1178, pp. 79- 91 ,(2008) , 10.1016/J.CHROMA.2007.11.044
John G. Atwood, Marcel J.E. Golay, Dispersion of peaks by short straight open tubes in liquid chromatography systems Journal of Chromatography A. ,vol. 218, pp. 97- 122 ,(1981) , 10.1016/S0021-9673(00)82050-6
Marcel J.E. Golay, John G. Atwood, Early phases of the dispersion of a sample injected in poiseuille flow Journal of Chromatography A. ,vol. 186, pp. 353- 370 ,(1979) , 10.1016/S0021-9673(00)95261-0
Oliver Kaltenbrunner, Alois Jungbauer, Shuichi Yamamoto, Prediction of the preparative chromatography performance with a very small column Journal of Chromatography A. ,vol. 760, pp. 41- 53 ,(1997) , 10.1016/S0021-9673(96)00689-9
Barry L. Karger, Michel. Martin, Georges. Guiochon, Role of column parameters and injection volume on detection limits in liquid chromatography Analytical Chemistry. ,vol. 46, pp. 1640- 1647 ,(1974) , 10.1021/AC60348A053