In vivo dosimetry during conformal therapy of prostatic cancer

作者: M. Essers , J.H. Lanson , B.J. Mijnheer

DOI: 10.1016/0167-8140(93)90258-A

关键词:

摘要: Abstract In vivo dose measurements were performed during the simultaneous boost technique for prostatic cancer to check accuracy of calculations by a monitor unit calculation program and three-dimensional planning system. The large field are given simultaneously using customized 10 mm thick Roses-metal blocks in which is cut out. Following procedure quality assurance protocol this technique, at specification point has been determined dosimetry. measured was initially too high 5 out 16 patients, due unexpected differences two beams with same nominal beam different density correction femoral heads; therefore checked improved. also compared CT-based (3-D) system, average deviation 3-D system from 0.1% ± 1.2%. Entrance, midline exit values central axial plane, cranial plane under transmission block have treatment entrance is, on average, 3.4% higher than calculated AP up 5.5% lateral beams. Phantom showed that these not related patient set-up errors. For various points difference between about 0.5%. No systematic deviations found points. resulted mainly change percentage depth tray supporting block. Our results demonstrated every validity be rechecked. Using we able calculate very accurately dose-high precision technique.

参考文章(15)
S Heukelom, J H Lanson, B J Mijnheer, Comparison of entrance and exit dose measurements using ionization chambers and silicon diodes Physics in Medicine and Biology. ,vol. 36, pp. 47- 59 ,(1991) , 10.1088/0031-9155/36/1/005
B.J. Mijnheer, A.H.L. Aalbers, A.g. Visser, F.W. Wittkämper, Consistency and simplicity in the determination of absorbed dose to water in high-energy photon beams: a new code of practice. Radiotherapy and Oncology. ,vol. 7, pp. 371- 384 ,(1986) , 10.1016/S0167-8140(86)80068-8
G Rikner, E Grusell, General specifications for silicon semiconductors for use in radiation dosimetry Physics in Medicine and Biology. ,vol. 32, pp. 1109- 1117 ,(1987) , 10.1088/0031-9155/32/9/004
Göran Rikner, Erik Grusell, Patient dose measurements in photon fields by means of silicon semiconductor detectors Medical Physics. ,vol. 14, pp. 870- 873 ,(1987) , 10.1118/1.596015
S. Heukelom, J.H. Lanson, B.J. Mijnheer, Quality assurance of the simultaneous boost technique for prostatic cancer: dosimetric aspects Radiotherapy and Oncology. ,vol. 30, pp. 74- 82 ,(1994) , 10.1016/0167-8140(94)90012-4
Bo Nilsson, Bengt-Inge Rudén, Bruno Sorcini, Characteristics of silicon diodes as patient dosemeters in external radiation therapy. Radiotherapy and Oncology. ,vol. 11, pp. 279- 288 ,(1988) , 10.1016/0167-8140(88)90011-4
G. Leunens, J. Van Dam, A. Dutreix, E. van der Schueren, Quality assurance in radiotherapy by in vivo dosimetry. 1. Entrance dose measurements, a reliable procedure Radiotherapy and Oncology. ,vol. 17, pp. 141- 151 ,(1990) , 10.1016/0167-8140(90)90102-3
Pin-Hua Huang, Lee M. Chin, Bengt E. Bjärngard, Scattered photons produced by beam-modifying filters Medical Physics. ,vol. 13, pp. 57- 63 ,(1986) , 10.1118/1.595923
B.J. Mijnheer, J.J. Battermann, A. Wambersie, What degree of accuracy is required and can be achieved in photon and neutron therapy Radiotherapy and Oncology. ,vol. 8, pp. 237- 252 ,(1987) , 10.1016/S0167-8140(87)80247-5
Joos V. Lebesque, Ronald B. Keus, The simultaneous boost technique: the concept of relative normalized total dose. Radiotherapy and Oncology. ,vol. 22, pp. 45- 55 ,(1991) , 10.1016/0167-8140(91)90068-R